<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-07T23:31:27.609459+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2021-avi-176</id>
    <title>certfr-2021-avi-176 — De multiples vulnérabilités ont été découvertes dans les produits
Siemens. Certaines d'entre elles permettent à un atta…</title>
    <updated>2026-10-07T23:31:27.613551+00:00</updated>
    <content>certfr-2021-avi-176</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2021-avi-176"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2021-16444</id>
    <title>cnvd-2021-16444</title>
    <updated>2026-10-07T23:31:27.613587+00:00</updated>
    <content>cnvd-2021-16444</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2021-16444"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-24844</id>
    <title>EUVD-2026-24844</title>
    <updated>2026-10-07T23:31:27.613602+00:00</updated>
    <content>EUVD-2026-24844</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-24844"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2021-25676</id>
    <title>fkie_cve-2021-25676</title>
    <updated>2026-10-07T23:31:27.613614+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions &gt;= V2.1 and &lt; V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2021-25676"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-pg2c-638q-xw3m</id>
    <title>GHSA-pg2c-638q-xw3m</title>
    <updated>2026-10-07T23:31:27.613642+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions &gt;= V2.1 and &lt; V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-pg2c-638q-xw3m"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2021-25676</id>
    <title>gsd-2021-25676</title>
    <updated>2026-10-07T23:31:27.613660+00:00</updated>
    <content>gsd-2021-25676</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2021-25676"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-21-068-02</id>
    <title>ICSA-21-068-02 — Siemens SCALANCE and RUGGEDCOM Devices SSH (Update A)</title>
    <updated>2026-10-07T23:31:27.613670+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-21-068-02"/>
  </entry>
</feed>