  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2021-01791</id>
    <title>bdu:2021-01791</title>
    <updated>2026-10-04T07:15:44.844044+00:00</updated>
    <content>bdu:2021-01791</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2021-01791"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2020-avi-726</id>
    <title>certfr-2020-avi-726 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider Electric. Certaines d'entre elles permetten…</title>
    <updated>2026-10-04T07:15:44.844098+00:00</updated>
    <content>certfr-2020-avi-726</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2020-avi-726"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2021-29456</id>
    <title>cnvd-2021-29456</title>
    <updated>2026-10-04T07:15:44.844132+00:00</updated>
    <content>cnvd-2021-29456</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2021-29456"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-37989</id>
    <title>EUVD-2026-37989</title>
    <updated>2026-10-04T07:15:44.844158+00:00</updated>
    <content>EUVD-2026-37989</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-37989"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2020-7571</id>
    <title>fkie_cve-2020-7571</title>
    <updated>2026-10-04T07:15:44.844189+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Reflected) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a Cross-Site Scripting reflected attack against other WebReport users.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2020-7571"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-3v2j-f789-x3jr</id>
    <title>GHSA-3v2j-f789-x3jr</title>
    <updated>2026-10-04T07:15:44.844238+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A CWE-79 Multiple Improper Neutralization of Input During Web Page Generation (Cross-site Scripting Reflected) vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a Cross-Site Scripting reflected attack against other WebReport users.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-3v2j-f789-x3jr"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2020-7571</id>
    <title>gsd-2020-7571</title>
    <updated>2026-10-04T07:15:44.844271+00:00</updated>
    <content>gsd-2020-7571</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2020-7571"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-21-063-02</id>
    <title>ICSA-21-063-02 — ICSA-21-063-02_Schneider Electric EcoStruxure Building Operation (EBO)</title>
    <updated>2026-10-04T07:15:44.844297+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An unrestricted upload of a file with dangerous type vulnerability could allow an authenticated remote user to upload arbitrary files due to incorrect verification of user supplied files and achieve remote code execution.CVE-2020-7569 has been assigned to this vulnerability. A CVSS v3 base score of 4.6 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:L). An improper neutralization of an input during webpage generation vulnerability could allow an authenticated remote user to inject arbitrary web script or HTML due to incorrect sanitization of user-supplied data and achieve a stored cross-site scripting attack against other WebReport users.CVE-2020-7570 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:L). Multiple improper neutralizations of an input during webpage generation vulnerabilities could allow a remote attacker to inject arbitrary web script or HTML due to incorrect sanitization of user supplied data and achieve a reflected cross-site scripting attack against other WebReport users.CVE-2020-7571 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). An improper restriction of XML external entity reference vulnerability could allow an authenticated remote user to inject arbitrary XML code and obtain disclosure of confidential data, cause…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-21-063-02"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/sevd-2020-315-04</id>
    <title>SEVD-2020-315-04 — EcoStruxure Building Operation (EBO)</title>
    <updated>2026-10-04T07:15:44.844408+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure Building Operation
(EBO) product offerings. More information on the product line can be found at the following link:
https://www.se.com/ww/en/product-range-presentation/62111-ecostruxure%E2%84%A2-
building-operation/?parent-subcategory-id=1210&amp;filter=business-2-building-automation-andcontrol#tabs-top
Failure to apply the mitigations/remediations provided below may risk various types of attacks 
and cause various types of impact (see information below for each vulnerability).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/sevd-2020-315-04"/>
  </entry>