  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2021-04172</id>
    <title>bdu:2021-04172</title>
    <updated>2026-10-05T11:53:10.095095+00:00</updated>
    <content>bdu:2021-04172</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2021-04172"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2020-avi-726</id>
    <title>certfr-2020-avi-726 — De multiples vulnérabilités ont été découvertes dans les produits
Schneider Electric. Certaines d'entre elles permetten…</title>
    <updated>2026-10-05T11:53:10.095132+00:00</updated>
    <content>certfr-2020-avi-726</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2020-avi-726"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2021-29460</id>
    <title>cnvd-2021-29460</title>
    <updated>2026-10-05T11:53:10.095153+00:00</updated>
    <content>cnvd-2021-29460</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2021-29460"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-46953</id>
    <title>EUVD-2026-46953</title>
    <updated>2026-10-05T11:53:10.095166+00:00</updated>
    <content>EUVD-2026-46953</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-46953"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2020-28211</id>
    <title>fkie_cve-2020-28211</title>
    <updated>2026-10-05T11:53:10.095177+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2020-28211"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-2x9m-ghpm-wjh6</id>
    <title>GHSA-2x9m-ghpm-wjh6</title>
    <updated>2026-10-05T11:53:10.095205+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-2x9m-ghpm-wjh6"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2020-28211</id>
    <title>gsd-2020-28211</title>
    <updated>2026-10-05T11:53:10.095234+00:00</updated>
    <content>gsd-2020-28211</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2020-28211"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/sevd-2020-315-07</id>
    <title>SEVD-2020-315-07 — PLC Simulator on EcoStruxure™ Control Expert and Process Expert</title>
    <updated>2026-10-05T11:53:10.095256+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Schneider Electric is aware of multiple vulnerabilities in its PLC Simulator for EcoStruxure™ Control Expert product.
PLC Simulator feature is part of the EcostruxureTM Control Expert and EcostruxureTM Process Expert software and it helps users to review and test their configurations files in a simulation environment; it is not intended to be used as a controller CPU in a production environment.
Failure to apply the mitigations provided below may risk unauthorized command execution or denial of service, which could result in undesired actions by the PLC simulator software.
March 2023 Update: An additional mitigation has been provided using a Cybersecurity Application Note (page 3).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/sevd-2020-315-07"/>
  </entry>