<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-02T23:55:13.642898+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2020-avi-800</id>
    <title>certfr-2020-avi-800 — De multiples vulnérabilités ont été découvertes dans les produits
Siemens. Certaines d'entre elles permettent à un atta…</title>
    <updated>2026-10-02T23:55:13.794377+00:00</updated>
    <content>certfr-2020-avi-800</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2020-avi-800"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2020-70936</id>
    <title>cnvd-2020-70936</title>
    <updated>2026-10-02T23:55:13.794424+00:00</updated>
    <content>cnvd-2020-70936</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2020-70936"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-45507</id>
    <title>EUVD-2026-45507</title>
    <updated>2026-10-02T23:55:13.794440+00:00</updated>
    <content>EUVD-2026-45507</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-45507"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2020-25232</id>
    <title>fkie_cve-2020-25232</title>
    <updated>2026-10-02T23:55:13.794451+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions &lt; V8.3). Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port 8080/tcp.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2020-25232"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-5fx7-6vcj-vqfc</id>
    <title>GHSA-5fx7-6vcj-vqfc</title>
    <updated>2026-10-02T23:55:13.794482+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions &lt; V8.3). Due to the usage of an insecure random number generation function and a deprecated cryptographic function, an attacker could extract the key that is used when communicating with an affected device on port 8080/tcp.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-5fx7-6vcj-vqfc"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2020-25232</id>
    <title>gsd-2020-25232</title>
    <updated>2026-10-02T23:55:13.794499+00:00</updated>
    <content>gsd-2020-25232</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2020-25232"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-20-343-10</id>
    <title>ICSA-20-343-10 — Siemens LOGO! 8 BM</title>
    <updated>2026-10-02T23:55:13.794510+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port. A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port. A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port. A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port. A service available on port 10005/tcp of the affected devices could allow complete access to all services without authorization. An attacker could gain full control over an affected device, if he has access to this service. The system manual recommends to protect access to this port. A service available on port 10005/tcp of the affected devices could allow…</p>