<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-04T15:26:55.021413+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-173705</id>
    <title>EUVD-2026-173705</title>
    <updated>2026-10-04T15:26:55.101595+00:00</updated>
    <content>EUVD-2026-173705</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-173705"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2020-12516</id>
    <title>fkie_cve-2020-12516</title>
    <updated>2026-10-04T15:26:55.101630+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2020-12516"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-wm2q-rjqh-v4ff</id>
    <title>GHSA-wm2q-rjqh-v4ff</title>
    <updated>2026-10-04T15:26:55.101662+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-wm2q-rjqh-v4ff"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2020-12516</id>
    <title>gsd-2020-12516</title>
    <updated>2026-10-04T15:26:55.101678+00:00</updated>
    <content>gsd-2020-12516</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2020-12516"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-20-308-01</id>
    <title>ICSA-20-308-01 — WAGO Series 750-88x and 750-352 (Update A)</title>
    <updated>2026-10-04T15:26:55.101689+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An attacker can execute a denial-of-service attack by sending a series of maliciously constructed packets to HTTP(S) Ports 80/443, which may cause the device to crash.CVE-2020-12516 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-20-308-01"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/vde-2020-042</id>
    <title>VDE-2020-042 — WAGO: PLC families 750-88x and 750-352 prone to DoS attack, versions &lt; FW10 (Update A)</title>
    <updated>2026-10-04T15:26:55.101709+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>The Web-Based Management (WBM) of WAGOs programmable logic controller (PLC) is typically used for administration, commissioning and updates.
Older firmware versions of the PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.</p>
<p>All newer Firmware releases since FW11, released in December 2017, are not affected.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/vde-2020-042"/>
  </entry>
</feed>
