<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-04T21:13:00.601016+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2020-28050</id>
    <title>cnvd-2020-28050</title>
    <updated>2026-10-04T21:13:00.666753+00:00</updated>
    <content>cnvd-2020-28050</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2020-28050"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-39916</id>
    <title>EUVD-2026-39916</title>
    <updated>2026-10-04T21:13:00.666791+00:00</updated>
    <content>EUVD-2026-39916</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-39916"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2020-10611</id>
    <title>fkie_cve-2020-10611</title>
    <updated>2026-10-04T21:13:00.666805+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2020-10611"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-grj9-c593-w7c6</id>
    <title>GHSA-grj9-c593-w7c6</title>
    <updated>2026-10-04T21:13:00.666835+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-grj9-c593-w7c6"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2020-10611</id>
    <title>gsd-2020-10611</title>
    <updated>2026-10-04T21:13:00.666851+00:00</updated>
    <content>gsd-2020-10611</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2020-10611"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-20-105-03</id>
    <title>ICSA-20-105-03 — Triangle MicroWorks SCADA Data Gateway</title>
    <updated>2026-10-04T21:13:00.666862+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>This vulnerability allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.CVE-2020-10615 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). This vulnerability allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.CVE-2020-10613 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). This vulnerability allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.CVE-2020-10611 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-20-105-03"/>
  </entry>
</feed>