<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-04T07:14:39.006677+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-175512</id>
    <title>EUVD-2026-175512</title>
    <updated>2026-10-04T07:14:39.215392+00:00</updated>
    <content>EUVD-2026-175512</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-175512"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2019-6528</id>
    <title>fkie_cve-2019-6528</title>
    <updated>2026-10-04T07:14:39.215504+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2019-6528"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-45cc-q6w5-96r8</id>
    <title>GHSA-45cc-q6w5-96r8</title>
    <updated>2026-10-04T07:14:39.215602+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-45cc-q6w5-96r8"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2019-6528</id>
    <title>gsd-2019-6528</title>
    <updated>2026-10-04T07:14:39.215635+00:00</updated>
    <content>gsd-2019-6528</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2019-6528"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-19-059-01</id>
    <title>ICSA-19-059-01 — PSI GridConnect Telecontrol</title>
    <updated>2026-10-04T07:14:39.215658+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.CVE-2019-6528 has been assigned to this vulnerability. A CVSS v3 base score of 8.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:N).</p>