  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2020-00988</id>
    <title>bdu:2020-00988</title>
    <updated>2026-10-02T13:57:19.340338+00:00</updated>
    <content>bdu:2020-00988</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2020-00988"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2020-avi-110</id>
    <title>certfr-2020-avi-110 — De multiples vulnérabilités ont été découvertes dans Moxa AWK-3131A.
Certaines d'entre elles permettent à un attaquant…</title>
    <updated>2026-10-02T13:57:19.340370+00:00</updated>
    <content>certfr-2020-avi-110</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2020-avi-110"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2020-13492</id>
    <title>cnvd-2020-13492</title>
    <updated>2026-10-02T13:57:19.340389+00:00</updated>
    <content>cnvd-2020-13492</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2020-13492"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-50026</id>
    <title>EUVD-2026-50026</title>
    <updated>2026-10-02T13:57:19.340402+00:00</updated>
    <content>EUVD-2026-50026</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-50026"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2019-5137</id>
    <title>fkie_cve-2019-5137</title>
    <updated>2026-10-02T13:57:19.340412+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The usage of hard-coded cryptographic keys within the ServiceAgent binary allows for the decryption of captured traffic across the network from or to the Moxa AWK-3131A firmware version 1.13.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2019-5137"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-2v7g-r6qx-cv4h</id>
    <title>GHSA-2v7g-r6qx-cv4h</title>
    <updated>2026-10-02T13:57:19.340438+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The usage of hard-coded cryptographic keys within the ServiceAgent binary allows for the decryption of captured traffic across the network from or to the Moxa AWK-3131A firmware version 1.13.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-2v7g-r6qx-cv4h"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2019-5137</id>
    <title>gsd-2019-5137</title>
    <updated>2026-10-02T13:57:19.340452+00:00</updated>
    <content>gsd-2019-5137</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2019-5137"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-20-063-04</id>
    <title>ICSA-20-063-04 — Moxa AWK-3131A Series Industrial AP/Bridge/Client</title>
    <updated>2026-10-02T13:57:19.340462+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A specially crafted menu selection string can cause an escape from the restricted console, resulting in system access as the root user. An attacker needs to be authenticated as a low-privilege user to trigger this vulnerability.CVE-2019-5136 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The usage of hard-coded cryptographic keys allows for the decryption of captured traffic across the network to or from the device.CVE-2019-5137 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). A specially crafted diagnostic script file can cause arbitrary commands to be executed, resulting in remote control over the device. An attacker needs to be authenticated as a low-privilege user to trigger this vulnerability.CVE-2019-5138 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). The device operating system contains an undocumented encryption password, allowing for the creation of custom diagnostic scripts.CVE-2019-5139 has been assigned to this vulnerability. A CVSS v3 base score of 6.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). A specially crafted diagnostic script file name can cause user input to be reflected in a subsequent system cal…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-20-063-04"/>
  </entry>