  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2019-avi-615</id>
    <title>certfr-2019-avi-615 — De multiples vulnérabilités ont été découvertes dans les produits
Siemens. Certaines d'entre elles permettent à un atta…</title>
    <updated>2026-10-03T11:17:25.181365+00:00</updated>
    <content>certfr-2019-avi-615</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2019-avi-615"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2019-44757</id>
    <title>cnvd-2019-44757</title>
    <updated>2026-10-03T11:17:25.181408+00:00</updated>
    <content>cnvd-2019-44757</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2019-44757"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-58712</id>
    <title>EUVD-2026-58712</title>
    <updated>2026-10-03T11:17:25.181424+00:00</updated>
    <content>EUVD-2026-58712</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-58712"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2019-18340</id>
    <title>fkie_cve-2019-18340</title>
    <updated>2026-10-03T11:17:25.181436+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>A vulnerability has been identified in Control Center Server (CCS) (All versions &lt; V1.5.0), Control Center Server (CCS) (All versions &gt;= V1.5.0), SiNVR/SiVMS Video Server (All versions &lt; V5.0.0), SiNVR/SiVMS Video Server (All versions &gt;= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store
user and device passwords by applying weak cryptography.</p>
<p>A local attacker could exploit this vulnerability to extract
the passwords from the user database and/or the device configuration files
to conduct further attacks.</p></div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2019-18340"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-9mrf-w63c-fxfh</id>
    <title>GHSA-9mrf-w63c-fxfh</title>
    <updated>2026-10-03T11:17:25.181469+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions). Both the SiNVR 3 Video Server and the Central Control Server (CCS) store user and device passwords by applying weak cryptography. A local attacker could exploit this vulnerability to extract the passwords from the user database and/or the device configuration files to conduct further attacks.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-9mrf-w63c-fxfh"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2019-18340</id>
    <title>gsd-2019-18340</title>
    <updated>2026-10-03T11:17:25.181486+00:00</updated>
    <content>gsd-2019-18340</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2019-18340"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-19-344-02</id>
    <title>ICSA-19-344-02 — Siemens and PKE SiNVR, SiVMS Video Server (Update A)</title>
    <updated>2026-10-03T11:17:25.181496+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The HTTP service (default specific port) of the SiNVR 3 Video Server contains an authentication bypass vulnerability, even when properly configured with enforced authentication. CVE-2019-13947, CVE-2019-18337, CVE-2019-18338, CVE-2019-18341, and CVE-2019-18342 have been moved to SSA-761844 and ICSA-21-103-10.CVE-2019-18339 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Both the SiNVR 3 Video Server and the CCS store user and device passwords by applying weak cryptography. CVE-2019-18340 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).. --------- End Update A Part 4 of 6 ---------CVE-2019-18340 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-19-344-02"/>
  </entry>