<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-02T19:50:51.715745+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/bdu:2020-02342</id>
    <title>bdu:2020-02342</title>
    <updated>2026-10-02T19:50:51.721086+00:00</updated>
    <content>bdu:2020-02342</content>
    <link href="https://cve.radiocsirt.org/vuln/bdu:2020-02342"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2020-avi-132</id>
    <title>certfr-2020-avi-132 — De multiples vulnérabilités ont été découvertes dans les produits
Siemens. Certaines d'entre elles permettent à un atta…</title>
    <updated>2026-10-02T19:50:51.721117+00:00</updated>
    <content>certfr-2020-avi-132</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2020-avi-132"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2020-19250</id>
    <title>cnvd-2020-19250</title>
    <updated>2026-10-02T19:50:51.721136+00:00</updated>
    <content>cnvd-2020-19250</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2020-19250"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-324093</id>
    <title>EUVD-2026-324093</title>
    <updated>2026-10-02T19:50:51.721148+00:00</updated>
    <content>EUVD-2026-324093</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-324093"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2019-18336</id>
    <title>fkie_cve-2019-18336</title>
    <updated>2026-10-02T19:50:51.721158+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions &lt; V3.X.17), SIMATIC TDC CP51M1 (All versions &lt; V1.1.8), SIMATIC TDC CPU555 (All versions &lt; V1.1.1), SINUMERIK 840D sl (All versions &lt; V4.8.6), SINUMERIK 840D sl (All versions &lt; V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2019-18336"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-q53p-vg4g-3rxp</id>
    <title>GHSA-q53p-vg4g-3rxp</title>
    <updated>2026-10-02T19:50:51.721187+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions &lt; V3.X.17), SINUMERIK 840D sl (All versions). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-q53p-vg4g-3rxp"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2019-18336</id>
    <title>gsd-2019-18336</title>
    <updated>2026-10-02T19:50:51.721205+00:00</updated>
    <content>gsd-2019-18336</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2019-18336"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-20-070-02</id>
    <title>ICSA-20-070-02 — Siemens SIMATIC S7-300 CPUs and SINUMERIK Controller over Profinet (Update A)</title>
    <updated>2026-10-02T19:50:51.721215+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-20-070-02"/>