<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-05T10:23:54.413685+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2019-31326</id>
    <title>cnvd-2019-31326</title>
    <updated>2026-10-05T10:23:54.493060+00:00</updated>
    <content>cnvd-2019-31326</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2019-31326"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-54089</id>
    <title>EUVD-2026-54089</title>
    <updated>2026-10-05T10:23:54.493097+00:00</updated>
    <content>EUVD-2026-54089</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-54089"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2019-10988</id>
    <title>fkie_cve-2019-10988</title>
    <updated>2026-10-05T10:23:54.493112+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2019-10988"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-wrfj-h54j-3h3q</id>
    <title>GHSA-wrfj-h54j-3h3q</title>
    <updated>2026-10-05T10:23:54.493142+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-wrfj-h54j-3h3q"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2019-10988</id>
    <title>gsd-2019-10988</title>
    <updated>2026-10-05T10:23:54.493159+00:00</updated>
    <content>gsd-2019-10988</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2019-10988"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsma-19-241-02</id>
    <title>ICSMA-19-241-02 — Philips HDI 4000 Ultrasound</title>
    <updated>2026-10-05T10:23:54.493170+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>The HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product.CVE-2019-10988 has been assigned to this vulnerability. A CVSS v3 base score of 3.0 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N).</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsma-19-241-02"/>
  </entry>
</feed>
