<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-03T21:32:08.026498+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2017-avi-279</id>
    <title>certfr-2017-avi-279 — De multiples vulnérabilités ont été corrigées dans &lt;span
class="textit"&gt;les produits Siemens&lt;/span&gt;. Elles permettent à…</title>
    <updated>2026-10-03T21:32:08.767069+00:00</updated>
    <content>certfr-2017-avi-279</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2017-avi-279"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2017-24122</id>
    <title>cnvd-2017-24122</title>
    <updated>2026-10-03T21:32:08.767108+00:00</updated>
    <content>cnvd-2017-24122</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2017-24122"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-77307</id>
    <title>EUVD-2026-77307</title>
    <updated>2026-10-03T21:32:08.767123+00:00</updated>
    <content>EUVD-2026-77307</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-77307"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2017-12734</id>
    <title>fkie_cve-2017-12734</title>
    <updated>2026-10-03T21:32:08.767141+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions &lt; V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2017-12734"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-p45c-2j4h-j2xg</id>
    <title>GHSA-p45c-2j4h-j2xg</title>
    <updated>2026-10-03T21:32:08.767189+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions &lt; V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-p45c-2j4h-j2xg"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2017-12734</id>
    <title>gsd-2017-12734</title>
    <updated>2026-10-03T21:32:08.767231+00:00</updated>
    <content>gsd-2017-12734</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2017-12734"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-17-243-02</id>
    <title>ICSA-17-243-02 — Siemens LOGO! (Update A)</title>
    <updated>2026-10-03T21:32:08.767251+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks. An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-17-243-02"/>
  </entry>
</feed>