<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://cve.radiocsirt.org/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-10-16T12:27:13.237474+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>csirt@opendfir.org</email>
  </author>
  <link href="https://cve.radiocsirt.org" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2017-25721</id>
    <title>cnvd-2017-25721</title>
    <updated>2026-10-16T12:27:13.301305+00:00</updated>
    <content>cnvd-2017-25721</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2017-25721"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-77298</id>
    <title>EUVD-2026-77298</title>
    <updated>2026-10-16T12:27:13.301359+00:00</updated>
    <content>EUVD-2026-77298</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-77298"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2017-12725</id>
    <title>fkie_cve-2017-12725</title>
    <updated>2026-10-16T12:27:13.301383+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2017-12725"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-chgj-p4c2-8wqj</id>
    <title>GHSA-chgj-p4c2-8wqj</title>
    <updated>2026-10-16T12:27:13.301435+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-chgj-p4c2-8wqj"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2017-12725</id>
    <title>gsd-2017-12725</title>
    <updated>2026-10-16T12:27:13.301473+00:00</updated>
    <content>gsd-2017-12725</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2017-12725"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsma-17-250-02a</id>
    <title>ICSMA-17-250-02A — Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)</title>
    <updated>2026-10-16T12:27:13.301497+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsma-17-250-02a"/>
  </entry>