  <entry>
    <id>https://cve.radiocsirt.org/vuln/certfr-2017-avi-279</id>
    <title>certfr-2017-avi-279 — De multiples vulnérabilités ont été corrigées dans &lt;span
class="textit"&gt;les produits Siemens&lt;/span&gt;. Elles permettent à…</title>
    <updated>2026-10-03T07:34:30.505137+00:00</updated>
    <content>certfr-2017-avi-279</content>
    <link href="https://cve.radiocsirt.org/vuln/certfr-2017-avi-279"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2017-24363</id>
    <title>cnvd-2017-24363</title>
    <updated>2026-10-03T07:34:30.505173+00:00</updated>
    <content>cnvd-2017-24363</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2017-24363"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-76937</id>
    <title>EUVD-2026-76937</title>
    <updated>2026-10-03T07:34:30.505189+00:00</updated>
    <content>EUVD-2026-76937</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-76937"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2017-12069</id>
    <title>fkie_cve-2017-12069</title>
    <updated>2026-10-03T07:34:30.505201+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions &lt; V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions &lt; V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2017-12069"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-jj7f-wqmm-8q5f</id>
    <title>GHSA-jj7f-wqmm-8q5f</title>
    <updated>2026-10-03T07:34:30.505231+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions &lt; V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions &lt; V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-jj7f-wqmm-8q5f"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2017-12069</id>
    <title>gsd-2017-12069</title>
    <updated>2026-10-03T07:34:30.505250+00:00</updated>
    <content>gsd-2017-12069</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2017-12069"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsa-17-243-01</id>
    <title>ICSA-17-243-01 — Siemens OPC UA Protocol Stack Discovery Service (Update E)</title>
    <updated>2026-10-03T07:34:30.505260+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker. To execute the attack, the attacker must have network access to the affected devices.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsa-17-243-01"/>