  <entry>
    <id>https://cve.radiocsirt.org/vuln/cnvd-2015-05145</id>
    <title>cnvd-2015-05145</title>
    <updated>2026-10-10T01:36:37.214541+00:00</updated>
    <content>cnvd-2015-05145</content>
    <link href="https://cve.radiocsirt.org/vuln/cnvd-2015-05145"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/euvd-2026-153162</id>
    <title>EUVD-2026-153162</title>
    <updated>2026-10-10T01:36:37.214592+00:00</updated>
    <content>EUVD-2026-153162</content>
    <link href="https://cve.radiocsirt.org/vuln/euvd-2026-153162"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/fkie_cve-2003-1603</id>
    <title>fkie_cve-2003-1603</title>
    <updated>2026-10-10T01:36:37.214607+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) "2" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/fkie_cve-2003-1603"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/ghsa-cxq8-frpg-8q64</id>
    <title>GHSA-cxq8-frpg-8q64</title>
    <updated>2026-10-10T01:36:37.214635+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) "2" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors.</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/ghsa-cxq8-frpg-8q64"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/gsd-2003-1603</id>
    <title>gsd-2003-1603</title>
    <updated>2026-10-10T01:36:37.214651+00:00</updated>
    <content>gsd-2003-1603</content>
    <link href="https://cve.radiocsirt.org/vuln/gsd-2003-1603"/>
  </entry>
  <entry>
    <id>https://cve.radiocsirt.org/vuln/icsma-18-037-02</id>
    <title>ICSMA-18-037-02 — GE Medical Devices Vulnerability</title>
    <updated>2026-10-10T01:36:37.214662+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors. GE Healthcare Discovery 530C has a password of #bigguy1 for the (1) acqservice user and (2) wsservice user of the Xeleris System, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.  GE Healthcare Discovery NM 750b has a password of 2getin for the insite account for (1) Telnet and (2) FTP, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. GE Healthcare Discovery XR656 and XR656 G2 has a password of (1) 2getin for the insite user, (2) 4$xray for the xruser user, and (3) #superxr for the root user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. GE Healthcare Precision THUNIS-800+ has a default password of (1) 1973 for the factor…</p>
      </div>
    </content>
    <link href="https://cve.radiocsirt.org/vuln/icsma-18-037-02"/>
  </entry>