CWE-78
AllowedImproper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Abstraction: Base · Status: Stable
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.
9614 vulnerabilities reference this CWE, most recent first.
CVE-2026-80152 (GCVE-0-2026-80152)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:22 – Updated: 2026-09-26 13:29- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.3
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80152",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:49:36.568082Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:52:24.941Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:54.538Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-script-schedule"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set script schedule",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80152",
"datePublished": "2026-09-22T15:22:09.965Z",
"dateReserved": "2026-08-25T20:43:54.262Z",
"dateUpdated": "2026-09-26T13:29:54.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80151 (GCVE-0-2026-80151)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:21 – Updated: 2026-09-26 13:29- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.3
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80151",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-25T23:35:00.564701Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-25T23:35:17.426Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000 before firmware v9.7.0.3, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set nfs download command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-26T13:29:53.855Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.3R3/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-os-command-injection-via-set-nfs-download"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices OS Command Injection via set nfs download",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80151",
"datePublished": "2026-09-22T15:21:45.246Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-26T13:29:53.855Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80145 (GCVE-0-2026-80145)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:18 – Updated: 2026-09-24 19:02- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80145",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-23T15:47:50.948392Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-23T15:47:57.416Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set cifs password command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:02:15.483Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-set-cifs-password"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via set cifs password",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80145",
"datePublished": "2026-09-22T15:18:34.859Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:02:15.483Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80144 (GCVE-0-2026-80144)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:17 – Updated: 2026-09-24 19:02- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80144",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T15:43:42.780303Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:43:55.512Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom write command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:02:33.612Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-write"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom write",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80144",
"datePublished": "2026-09-22T15:17:45.543Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:02:33.612Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80143 (GCVE-0-2026-80143)
Vulnerability from cvelistv5 – Published: 2026-09-22 15:17 – Updated: 2026-09-24 19:02- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://revrb.net/2026/09/21/revrb-lantern.html | technical-description |
| https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/ | patch |
| https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/ | patch |
| https://www.vulncheck.com/advisories/lantronix-au… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| LANTRONIX | SLC8000 |
Affected:
0 , < 9.7.0.2
(custom)
|
|
| LANTRONIX | EMG8500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | EMG7500 |
Affected:
0 , < 9.7.0.1
(custom)
|
|
| LANTRONIX | SLB882 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-03 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLCx-02 |
Affected:
*
(custom)
|
|
| LANTRONIX | SLC9000 |
Affected:
0 , < 9.7.0.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80143",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T17:22:12.191184Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T17:44:26.836Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SLC8000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG8500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EMG7500",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLB882",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SLCx-03",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLCx-02",
"vendor": "LANTRONIX",
"versions": [
{
"status": "affected",
"version": "*",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SLC9000",
"vendor": "LANTRONIX",
"versions": [
{
"lessThan": "9.7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "RE/VRb"
}
],
"datePublic": "2026-09-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands as root by exploiting an undocumented mfc eeprom read command that passes unsanitized user input to a system() call. Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T19:02:44.035Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Researcher Disclosure",
"tags": [
"technical-description"
],
"url": "https://revrb.net/2026/09/21/revrb-lantern.html"
},
{
"name": "SLC8000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
},
{
"name": "EMG8500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
},
{
"name": "EMG7500 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
},
{
"name": "SLC9000 Firmware",
"tags": [
"patch"
],
"url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-read"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lantronix Autonomous Out-of-Band Devices CLI Command Injection via mfc eeprom read",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80143",
"datePublished": "2026-09-22T15:17:21.739Z",
"dateReserved": "2026-08-25T20:43:54.261Z",
"dateUpdated": "2026-09-24T19:02:44.035Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80138 (GCVE-0-2026-80138)
Vulnerability from cvelistv5 – Published: 2026-08-25 22:12 – Updated: 2026-08-26 12:23- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://github.com/MacWarrior/clipbucket-v5 | product |
| https://github.com/MacWarrior/clipbucket-v5/commi… | patch |
| https://github.com/MacWarrior/clipbucket-v5/blob/… | technical-description |
| https://github.com/MacWarrior/clipbucket-v5/blob/… | technical-description |
| https://www.vulncheck.com/advisories/clipbucket-v… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| MacWarrior | clipbucket-v5 |
Affected:
5.5.1 , ≤ 5.5.3-#153
(custom)
cpe:2.3:a:clip-bucket:clipbucket:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80138",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-26T12:23:42.630366Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T12:23:55.095Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://github.com/MacWarrior/clipbucket-v5",
"defaultStatus": "unaffected",
"packageURL": "pkg:github/MacWarrior/clipbucket-v5",
"product": "clipbucket-v5",
"repo": "https://github.com/MacWarrior/clipbucket-v5",
"vendor": "MacWarrior",
"versions": [
{
"lessThanOrEqual": "5.5.3-#153",
"status": "affected",
"version": "5.5.1",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:clip-bucket:clipbucket:*:*:*:*:*:*:*:*",
"versionEndIncluding": "5.5.3-#153",
"versionStartIncluding": "5.5.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Adam Nurudini"
}
],
"datePublic": "2026-08-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ClipBucket V5\u0027s web installer fails to properly validate or escape the php_cli_filepath parameter before passing it to shell execution. Unauthenticated attackers can submit a crafted POST request to the installer with a malicious php_cli_filepath value to execute arbitrary commands as the web server user."
}
],
"metrics": [
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T22:12:23.914Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"product"
],
"url": "https://github.com/MacWarrior/clipbucket-v5"
},
{
"tags": [
"patch"
],
"url": "https://github.com/MacWarrior/clipbucket-v5/commit/36e7c6cfd81f62a091d2aeef96a8fc2fc2d85dc4"
},
{
"tags": [
"technical-description"
],
"url": "https://github.com/MacWarrior/clipbucket-v5/blob/5.5.3-%23153/upload/includes/classes/system.class.php"
},
{
"tags": [
"technical-description"
],
"url": "https://github.com/MacWarrior/clipbucket-v5/blob/5.5.3-%23153/upload/cb_install/functions_install.php"
},
{
"name": "VulnCheck Advisory: ClipBucket V5 5.5.1 through 5.5.3-#153 OS Command Injection via Installer php_cli_filepath Parameter",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/clipbucket-v5-5.5.1-through-5.5.3-153-os-command-injection-via-installer-php-cli-filepath-parameter"
}
],
"title": "ClipBucket V5 5.5.1 through 5.5.3-#153 OS Command Injection via Installer php_cli_filepath Parameter",
"x_generator": {
"engine": "vulncheck-endgame"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-80138",
"datePublished": "2026-08-25T22:12:23.914Z",
"dateReserved": "2026-08-25T20:23:31.117Z",
"dateUpdated": "2026-08-26T12:23:55.095Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-80127 (GCVE-0-2026-80127)
Vulnerability from cvelistv5 – Published: 2026-09-07 15:59 – Updated: 2026-09-08 12:50- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-in/00050342… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Secure Connect Gateway 5.0 - Application |
Affected:
0 , < 5.36.00.00 or later
(semver)
|
|
| Dell | Secure Connect Gateway 5.0 - Appliance |
Affected:
0 , < 5.36.00.16 or later
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-80127",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-08T12:46:07.004993Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T12:50:11.528Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Secure Connect Gateway 5.0 - Application",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.36.00.00 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Secure Connect Gateway 5.0 - Appliance",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.36.00.16 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-08-31T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to elevation of privileges."
}
],
"value": "Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to elevation of privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-07T15:59:45.073Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-in/000503426/dsa-2026-382-security-update-for-dell-secure-connect-gateway-virtual-edition-multiple-vulnerabilities?msockid=3021cac2195069ed3194ddad186a68f9"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-80127",
"datePublished": "2026-09-07T15:59:45.073Z",
"dateReserved": "2026-08-25T20:04:12.994Z",
"dateUpdated": "2026-09-08T12:50:11.528Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-79992 (GCVE-0-2026-79992)
Vulnerability from cvelistv5 – Published: 2026-08-25 17:16 – Updated: 2026-09-24 20:22- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://access.redhat.com/security/cve/CVE-2026-79992 | vdb-entryx_refsource_REDHAT |
| https://bugzilla.redhat.com/show_bug.cgi?id=2523665 | issue-trackingx_refsource_REDHAT |
| http://www.openwall.com/lists/oss-security/2026/0… |
| Vendor | Product | Version | |
|---|---|---|---|
| Red Hat | Red Hat Enterprise Linux 10 |
cpe:/o:redhat:enterprise_linux:10
|
|
| Red Hat | Red Hat Enterprise Linux 6 |
cpe:/o:redhat:enterprise_linux:6
|
|
| Red Hat | Red Hat Enterprise Linux 7 |
cpe:/o:redhat:enterprise_linux:7
|
|
| Red Hat | Red Hat Enterprise Linux 8 |
cpe:/o:redhat:enterprise_linux:8
|
|
| Red Hat | Red Hat Enterprise Linux 9 |
cpe:/o:redhat:enterprise_linux:9
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-79992",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-25T17:32:22.093371Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-25T17:43:23.591Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-08-26T17:56:00.585Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://www.openwall.com/lists/oss-security/2026/08/26/15"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
"cpes": [
"cpe:/o:redhat:enterprise_linux:10"
],
"defaultStatus": "affected",
"packageName": "emacs",
"product": "Red Hat Enterprise Linux 10",
"vendor": "Red Hat"
},
{
"collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
"cpes": [
"cpe:/o:redhat:enterprise_linux:6"
],
"defaultStatus": "affected",
"packageName": "emacs",
"product": "Red Hat Enterprise Linux 6",
"vendor": "Red Hat"
},
{
"collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
"cpes": [
"cpe:/o:redhat:enterprise_linux:7"
],
"defaultStatus": "affected",
"packageName": "emacs",
"product": "Red Hat Enterprise Linux 7",
"vendor": "Red Hat"
},
{
"collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
"cpes": [
"cpe:/o:redhat:enterprise_linux:8"
],
"defaultStatus": "affected",
"packageName": "emacs",
"product": "Red Hat Enterprise Linux 8",
"vendor": "Red Hat"
},
{
"collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
"cpes": [
"cpe:/o:redhat:enterprise_linux:9"
],
"defaultStatus": "affected",
"packageName": "emacs",
"product": "Red Hat Enterprise Linux 9",
"vendor": "Red Hat"
}
],
"datePublic": "2026-08-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A flaw was found in Emacs TRAMP. A local attacker could exploit this vulnerability by processing maliciously crafted filenames. This occurs because TRAMP concatenates login arguments without proper sanitization, which are then passed to a local shell. Successful exploitation could lead to arbitrary code execution."
}
],
"metrics": [
{
"other": {
"content": {
"namespace": "https://access.redhat.com/security/updates/classification/",
"value": "Important"
},
"type": "Red Hat severity rating"
}
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-24T20:22:00.674Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"tags": [
"vdb-entry",
"x_refsource_REDHAT"
],
"url": "https://access.redhat.com/security/cve/CVE-2026-79992"
},
{
"name": "RHBZ#2523665",
"tags": [
"issue-tracking",
"x_refsource_REDHAT"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2523665"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-08-25T16:40:51.291Z",
"value": "Reported to Red Hat."
},
{
"lang": "en",
"time": "2026-08-21T00:00:00.000Z",
"value": "Made public."
}
],
"title": "Emacs: emacs: command injection via crafted filenames in tramp",
"workarounds": [
{
"lang": "en",
"value": "Users of Emacs TRAMP should avoid processing untrusted filenames or interacting with remote systems that may contain maliciously crafted file names. This operational control reduces the risk of local shell command injection."
}
],
"x_generator": {
"engine": "cvelib 1.8.0"
},
"x_redhatCweChain": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2026-79992",
"datePublished": "2026-08-25T17:16:28.309Z",
"dateReserved": "2026-08-25T16:39:44.534Z",
"dateUpdated": "2026-09-24T20:22:00.674Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-79916 (GCVE-0-2026-79916)
Vulnerability from cvelistv5 – Published: 2026-09-21 20:34 – Updated: 2026-09-22 15:39- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
| URL | Tags |
|---|---|
| https://github.com/1Panel-dev/MaxKB/security/advi… | x_refsource_CONFIRM |
| https://github.com/1Panel-dev/MaxKB/pull/6418 | x_refsource_MISC |
| https://github.com/1Panel-dev/MaxKB/commit/a1e413… | x_refsource_MISC |
| https://github.com/1Panel-dev/MaxKB/releases/tag/… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| 1Panel-dev | MaxKB |
Affected:
< 2.10.5-lts
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-79916",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-22T14:12:21.692945Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-22T15:39:19.409Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "MaxKB",
"vendor": "1Panel-dev",
"versions": [
{
"status": "affected",
"version": "\u003c 2.10.5-lts"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "MaxKB is an open-source AI assistant for enterprise. Prior to 2.10.5-lts, authenticated workspace members can inject control characters into AWS Bedrock access_key_id and secret_access_key fields that _update_aws_credentials writes to /root/.aws/credentials without safe parsing. An attacker can append a new AWS profile containing credential_process, then select that profile during a later model-validation request so botocore executes an attacker-controlled command as root. This vulnerability is fixed in 2.10.5-lts."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-21T20:34:47.530Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/1Panel-dev/MaxKB/security/advisories/GHSA-2324-7xjr-9qxg",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/1Panel-dev/MaxKB/security/advisories/GHSA-2324-7xjr-9qxg"
},
{
"name": "https://github.com/1Panel-dev/MaxKB/pull/6418",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/1Panel-dev/MaxKB/pull/6418"
},
{
"name": "https://github.com/1Panel-dev/MaxKB/commit/a1e413d196004421ab0953ee0baa13d4ca0fe3c4",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/1Panel-dev/MaxKB/commit/a1e413d196004421ab0953ee0baa13d4ca0fe3c4"
},
{
"name": "https://github.com/1Panel-dev/MaxKB/releases/tag/v2.10.5-lts",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/1Panel-dev/MaxKB/releases/tag/v2.10.5-lts"
}
],
"source": {
"advisory": "GHSA-2324-7xjr-9qxg",
"discovery": "UNKNOWN"
},
"title": "MaxKB AWS Bedrock model credential injection leads to remote code execution"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2026-79916",
"datePublished": "2026-09-21T20:34:47.530Z",
"dateReserved": "2026-08-25T14:59:32.746Z",
"dateUpdated": "2026-09-22T15:39:19.409Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-79898 (GCVE-0-2026-79898)
Vulnerability from cvelistv5 – Published: 2026-10-01 14:57 – Updated: 2026-10-01 15:28- CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
| Vendor | Product | Version | |
|---|---|---|---|
| Fortra | BoKS Manager |
Affected:
8.1.0.0 , ≤ 8.1.0.23
(custom)
Affected: 9.0.0.0 , ≤ 9.0.0.6 (custom) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-79898",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-01T15:15:26.791853Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-01T15:28:05.079Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"modules": [
"crlserver"
],
"product": "BoKS Manager",
"vendor": "Fortra",
"versions": [
{
"lessThanOrEqual": "8.1.0.23",
"status": "affected",
"version": "8.1.0.0",
"versionType": "custom"
},
{
"lessThanOrEqual": "9.0.0.6",
"status": "affected",
"version": "9.0.0.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eThe issue affects deployments that process configured CRL URLs. Exploitation requires an authenticated user who can add a CRL URL through one of the supported administration paths. In BCC, the user requires the CRLS add ABAC right. In WSI, the client requires permission to call addCACRLURL for the target domain and sufficient downstream BCCAS authority, through either the caller\u0027s forwarded BoKS session or WSI\u0027s configured domain account. These are network-accessible paths and do not require local sudo or suexec access. A non-root user of the cacrl command-line path requires a suitable sudo or suexec rule, which may be narrowly scoped to cacrl. Scheduled CRL import processes the URL automatically; a separately permitted download operation may also trigger processing.\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "The issue affects deployments that process configured CRL URLs. Exploitation requires an authenticated user who can add a CRL URL through one of the supported administration paths. In BCC, the user requires the CRLS add ABAC right. In WSI, the client requires permission to call addCACRLURL for the target domain and sufficient downstream BCCAS authority, through either the caller\u0027s forwarded BoKS session or WSI\u0027s configured domain account. These are network-accessible paths and do not require local sudo or suexec access. A non-root user of the cacrl command-line path requires a suitable sudo or suexec rule, which may be narrowly scoped to cacrl. Scheduled CRL import processes the URL automatically; a separately permitted download operation may also trigger processing."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Fortra BoKS Manager contains a command injection vulnerability in crlserver. An authenticated user authorized to add CRL URLs through BCC, the WSI REST or SOAP API, or the cacrl command-line interface could cause shell command substitution to be processed by crlserver as root on the BoKS Master. BCC and WSI provide network-accessible administration paths and do not require a local sudo or suexec rule; non-root use of cacrl requires such a rule."
}
],
"value": "Fortra BoKS Manager contains a command injection vulnerability in crlserver. An authenticated user authorized to add CRL URLs through BCC, the WSI REST or SOAP API, or the cacrl command-line interface could cause shell command substitution to be processed by crlserver as root on the BoKS Master. BCC and WSI provide network-accessible administration paths and do not require a local sudo or suexec rule; non-root use of cacrl requires such a rule."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88: OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-01T14:57:28.382Z",
"orgId": "df4dee71-de3a-4139-9588-11b62fe6c0ff",
"shortName": "Fortra"
},
"references": [
{
"url": "https://www.fortra.com/security/advisories/product-security/fi-2026-015"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eUpgrade to boks-server 8.1.0.24 or boks-server 9.0.0.7, as appropriate for the installed maintenance line.\u0026nbsp;\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Upgrade to boks-server 8.1.0.24 or boks-server 9.0.0.7, as appropriate for the installed maintenance line."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Fortra BoKS Manager crlserver command injection vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "df4dee71-de3a-4139-9588-11b62fe6c0ff",
"assignerShortName": "Fortra",
"cveId": "CVE-2026-79898",
"datePublished": "2026-10-01T14:57:28.382Z",
"dateReserved": "2026-08-25T14:50:10.463Z",
"dateUpdated": "2026-10-01T15:28:05.079Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Mitigation
If at all possible, use library calls rather than external processes to recreate the desired functionality.
Mitigation MIT-22
Strategy: Sandbox or Jail
- Run the code in a "jail" or similar sandbox environment that enforces strict boundaries between the process and the operating system. This may effectively restrict which files can be accessed in a particular directory or which commands can be executed by the software.
- OS-level examples include the Unix chroot jail, AppArmor, and SELinux. In general, managed code may provide some protection. For example, java.io.FilePermission in the Java SecurityManager allows the software to specify restrictions on file operations.
- This may not be a feasible solution, and it only limits the impact to the operating system; the rest of the application may still be subject to compromise.
- Be careful to avoid CWE-243 and other weaknesses related to jails.
Mitigation
Strategy: Attack Surface Reduction
For any data that will be used to generate a command to be executed, keep as much of that data out of external control as possible. For example, in web applications, this may require storing the data locally in the session's state instead of sending it out to the client in a hidden form field.
Mitigation MIT-15
For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
Mitigation MIT-4.3
Strategy: Libraries or Frameworks
- Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
- For example, consider using the ESAPI Encoding control [REF-45] or a similar tool, library, or framework. These will help the programmer encode outputs in a manner less prone to error.
Mitigation MIT-28
Strategy: Output Encoding
While it is risky to use dynamically-generated query strings, code, or commands that mix control and data together, sometimes it may be unavoidable. Properly quote arguments and escape any special characters within those arguments. The most conservative approach is to escape or filter all characters that do not pass an extremely strict allowlist (such as everything that is not alphanumeric or white space). If some special characters are still needed, such as white space, wrap each argument in quotes after the escaping/filtering step. Be careful of argument injection (CWE-88).
Mitigation
If the program to be executed allows arguments to be specified within an input file or from standard input, then consider using that mode to pass arguments instead of the command line.
Mitigation MIT-27
Strategy: Parameterization
- If available, use structured mechanisms that automatically enforce the separation between data and code. These mechanisms may be able to provide the relevant quoting, encoding, and validation automatically, instead of relying on the developer to provide this capability at every point where output is generated.
- Some languages offer multiple functions that can be used to invoke commands. Where possible, identify any function that invokes a command shell using a single string, and replace it with a function that requires individual arguments. These functions typically perform appropriate quoting and filtering of arguments. For example, in C, the system() function accepts a string that contains the entire command to be executed, whereas execl(), execve(), and others require an array of strings, one for each argument. In Windows, CreateProcess() only accepts one command at a time. In Perl, if system() is provided with an array of arguments, then it will quote each of the arguments.
Mitigation MIT-5
Strategy: Input Validation
- Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
- When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
- Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
- When constructing OS command strings, use stringent allowlists that limit the character set based on the expected value of the parameter in the request. This will indirectly limit the scope of an attack, but this technique is less important than proper output encoding and escaping.
- Note that proper output encoding, escaping, and quoting is the most effective solution for preventing OS command injection, although input validation may provide some defense-in-depth. This is because it effectively limits what will appear in output. Input validation will not always prevent OS command injection, especially if you are required to support free-form text fields that could contain arbitrary characters. For example, when invoking a mail program, you might need to allow the subject field to contain otherwise-dangerous inputs like ";" and ">" characters, which would need to be escaped or otherwise handled. In this case, stripping the character might reduce the risk of OS command injection, but it would produce incorrect behavior because the subject field would not be recorded as the user intended. This might seem to be a minor inconvenience, but it could be more important when the program relies on well-structured subject lines in order to pass messages to other components.
- Even if you make a mistake in your validation (such as forgetting one out of 100 input fields), appropriate encoding is still likely to protect you from injection-based attacks. As long as it is not done in isolation, input validation is still a useful technique, since it may significantly reduce your attack surface, allow you to detect some attacks, and provide other security benefits that proper encoding does not address.
Mitigation MIT-21
Strategy: Enforcement by Conversion
When the set of acceptable objects, such as filenames or URLs, is limited or known, create a mapping from a set of fixed input values (such as numeric IDs) to the actual filenames or URLs, and reject all other inputs.
Mitigation MIT-32
Strategy: Compilation or Build Hardening
Run the code in an environment that performs automatic taint propagation and prevents any command execution that uses tainted variables, such as Perl's "-T" switch. This will force the program to perform validation steps that remove the taint, although you must be careful to correctly validate your inputs so that you do not accidentally mark dangerous inputs as untainted (see CWE-183 and CWE-184).
Mitigation MIT-32
Strategy: Environment Hardening
Run the code in an environment that performs automatic taint propagation and prevents any command execution that uses tainted variables, such as Perl's "-T" switch. This will force the program to perform validation steps that remove the taint, although you must be careful to correctly validate your inputs so that you do not accidentally mark dangerous inputs as untainted (see CWE-183 and CWE-184).
Mitigation MIT-39
- Ensure that error messages only contain minimal details that are useful to the intended audience and no one else. The messages need to strike the balance between being too cryptic (which can confuse users) or being too detailed (which may reveal more than intended). The messages should not reveal the methods that were used to determine the error. Attackers can use detailed information to refine or optimize their original attack, thereby increasing their chances of success.
- If errors must be captured in some detail, record them in log messages, but consider what could occur if the log messages can be viewed by attackers. Highly sensitive information such as passwords should never be saved to log files.
- Avoid inconsistent messaging that might accidentally tip off an attacker about internal state, such as whether a user account exists or not.
- In the context of OS Command Injection, error information passed back to the user might reveal whether an OS command is being executed and possibly which command is being used.
Mitigation
Strategy: Sandbox or Jail
Use runtime policy enforcement to create an allowlist of allowable commands, then prevent use of any command that does not appear in the allowlist. Technologies such as AppArmor are available to do this.
Mitigation MIT-29
Strategy: Firewall
Use an application firewall that can detect attacks against this weakness. It can be beneficial in cases in which the code cannot be fixed (because it is controlled by a third party), as an emergency prevention measure while more comprehensive software assurance measures are applied, or to provide defense in depth [REF-1481].
Mitigation MIT-17
Strategy: Environment Hardening
Run your code using the lowest privileges that are required to accomplish the necessary tasks [REF-76]. If possible, create isolated accounts with limited privileges that are only used for a single task. That way, a successful attack will not immediately give the attacker access to the rest of the software or its environment. For example, database applications rarely need to run as the database administrator, especially in day-to-day operations.
Mitigation MIT-16
Strategy: Environment Hardening
When using PHP, configure the application so that it does not use register_globals. During implementation, develop the application so that it does not rely on this feature, but be wary of implementing a register_globals emulation that is subject to weaknesses such as CWE-95, CWE-621, and similar issues.
CAPEC-108: Command Line Execution through SQL Injection
An attacker uses standard SQL injection methods to inject data into the command line for execution. This could be done directly through misuse of directives such as MSSQL_xp_cmdshell or indirectly through injection of data into the database that would be interpreted as shell commands. Sometime later, an unscrupulous backend application (or could be part of the functionality of the same application) fetches the injected data stored in the database and uses this data as command line arguments without performing proper validation. The malicious data escapes that data plane by spawning new commands to be executed on the host.
CAPEC-15: Command Delimiters
An attack of this type exploits a programs' vulnerabilities that allows an attacker's commands to be concatenated onto a legitimate command with the intent of targeting other resources such as the file system or database. The system that uses a filter or denylist input validation, as opposed to allowlist validation is vulnerable to an attacker who predicts delimiters (or combinations of delimiters) not present in the filter or denylist. As with other injection attacks, the attacker uses the command delimiter payload as an entry point to tunnel through the application and activate additional attacks through SQL queries, shell commands, network scanning, and so on.
CAPEC-43: Exploiting Multiple Input Interpretation Layers
An attacker supplies the target software with input data that contains sequences of special characters designed to bypass input validation logic. This exploit relies on the target making multiples passes over the input data and processing a "layer" of special characters with each pass. In this manner, the attacker can disguise input that would otherwise be rejected as invalid by concealing it with layers of special/escape characters that are stripped off by subsequent processing steps. The goal is to first discover cases where the input validation layer executes before one or more parsing layers. That is, user input may go through the following logic in an application: <parser1> --> <input validator> --> <parser2>. In such cases, the attacker will need to provide input that will pass through the input validator, but after passing through parser2, will be converted into something that the input validator was supposed to stop.
CAPEC-6: Argument Injection
An attacker changes the behavior or state of a targeted application through injecting data or command syntax through the targets use of non-validated and non-filtered arguments of exposed services or methods.
CAPEC-88: OS Command Injection
In this type of an attack, an adversary injects operating system commands into existing application functions. An application that uses untrusted input to build command strings is vulnerable. An adversary can leverage OS command injection in an application to elevate privileges, execute arbitrary commands and compromise the underlying operating system.