Common Weakness Enumeration

CWE-312

Allowed

Cleartext Storage of Sensitive Information

Abstraction: Base · Status: Draft

The product stores sensitive information in cleartext within a resource that might be accessible to another control sphere.

1141 vulnerabilities reference this CWE, most recent first.

CVE-2017-9663 (GCVE-0-2017-9663)

Vulnerability from cvelistv5 – Published: 2018-01-09 21:00 – Updated: 2024-08-05 17:18
VLAI
Summary
An Cleartext Storage of Sensitive Information issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow a remote attacker to access an encryption key that is stored in cleartext in memory.
Severity
No CVSS data available.
CWE
References
Impacted products
Vendor Product Version
n/a General Motors and Shanghai OnStar (SOS) iOS Client Affected: General Motors and Shanghai OnStar (SOS) iOS Client
Date Public
2018-01-09 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:18:00.404Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-04"
          },
          {
            "name": "102481",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102481"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "General Motors and Shanghai OnStar (SOS) iOS Client",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "General Motors and Shanghai OnStar (SOS) iOS Client"
            }
          ]
        }
      ],
      "datePublic": "2018-01-09T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Cleartext Storage of Sensitive Information issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow a remote attacker to access an encryption key that is stored in cleartext in memory."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-01-12T10:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-04"
        },
        {
          "name": "102481",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102481"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-9663",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "General Motors and Shanghai OnStar (SOS) iOS Client",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "General Motors and Shanghai OnStar (SOS) iOS Client"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Cleartext Storage of Sensitive Information issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow a remote attacker to access an encryption key that is stored in cleartext in memory."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-04"
            },
            {
              "name": "102481",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102481"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-9663",
    "datePublished": "2018-01-09T21:00:00.000Z",
    "dateReserved": "2017-06-14T00:00:00.000Z",
    "dateUpdated": "2024-08-05T17:18:00.404Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9654 (GCVE-0-2017-9654)

Vulnerability from cvelistv5 – Published: 2018-04-24 15:00 – Updated: 2024-09-17 03:43
VLAI
Summary
The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext storage of sensitive information CWE-312
References
Impacted products
Vendor Product Version
Philips DoseWise Portal Affected: 1.1.7.333
Affected: 2.1.1.3069
Create a notification for this product.
Date Public
2017-08-17 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:18:00.345Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100471"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.philips.com/productsecurity"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DoseWise Portal",
          "vendor": "Philips",
          "versions": [
            {
              "status": "affected",
              "version": "1.1.7.333"
            },
            {
              "status": "affected",
              "version": "2.1.1.3069"
            }
          ]
        }
      ],
      "datePublic": "2017-08-17T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "Cleartext storage of sensitive information CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-25T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "100471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100471"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.philips.com/productsecurity"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2017-08-17T00:00:00",
          "ID": "CVE-2017-9654",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DoseWise Portal",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.1.7.333"
                          },
                          {
                            "version_value": "2.1.1.3069"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Philips"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext storage of sensitive information CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100471"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01"
            },
            {
              "name": "http://www.philips.com/productsecurity",
              "refsource": "CONFIRM",
              "url": "http://www.philips.com/productsecurity"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-9654",
    "datePublished": "2018-04-24T15:00:00.000Z",
    "dateReserved": "2017-06-14T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:43:28.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-3214 (GCVE-0-2017-3214)

Vulnerability from cvelistv5 – Published: 2017-06-20 00:00 – Updated: 2024-08-05 14:16
VLAI
Summary
The Milwaukee ONE-KEY Android mobile application stores the master token in plaintext in the apk binary.
Severity
No CVSS data available.
CWE
References
Impacted products
Vendor Product Version
Milwaukee Tool ONE-KEY Affected: unspecified
Create a notification for this product.
Date Public
2017-06-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:16:28.243Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://duo.com/blog/bug-hunting-drilling-into-the-internet-of-things-iot"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ONE-KEY",
          "vendor": "Milwaukee Tool",
          "versions": [
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "datePublic": "2017-06-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Milwaukee ONE-KEY Android mobile application stores the master token in plaintext in the apk binary."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-19T23:57:01.000Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://duo.com/blog/bug-hunting-drilling-into-the-internet-of-things-iot"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2017-3214",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ONE-KEY",
                      "version": {
                        "version_data": [
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Milwaukee Tool"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Milwaukee ONE-KEY Android mobile application stores the master token in plaintext in the apk binary."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://duo.com/blog/bug-hunting-drilling-into-the-internet-of-things-iot",
              "refsource": "MISC",
              "url": "https://duo.com/blog/bug-hunting-drilling-into-the-internet-of-things-iot"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2017-3214",
    "datePublished": "2017-06-20T00:00:00.000Z",
    "dateReserved": "2016-12-05T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:16:28.243Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-2672 (GCVE-0-2017-2672)

Vulnerability from cvelistv5 – Published: 2018-06-21 13:00 – Updated: 2024-08-05 14:02
VLAI
Summary
A flaw was found in foreman before version 1.15 in the logging of adding and registering images. An attacker with access to the foreman log file would be able to view passwords for provisioned systems in the log file, allowing them to access those systems.
CWE
References
Impacted products
Vendor Product Version
[UNKNOWN] foreman Affected: foreman 1.15
Create a notification for this product.
Date Public
2017-04-04 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.221Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://projects.theforeman.org/issues/19169"
          },
          {
            "name": "RHSA-2018:0336",
            "tags": [
              "vendor-advisory",
              "x_refsource_REDHAT",
              "x_transferred"
            ],
            "url": "https://access.redhat.com/errata/RHSA-2018:0336"
          },
          {
            "name": "97526",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97526"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2672"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "foreman",
          "vendor": "[UNKNOWN]",
          "versions": [
            {
              "status": "affected",
              "version": "foreman 1.15"
            }
          ]
        }
      ],
      "datePublic": "2017-04-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw was found in foreman before version 1.15 in the logging of adding and registering images. An attacker with access to the foreman log file would be able to view passwords for provisioned systems in the log file, allowing them to access those systems."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-22T09:57:01.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://projects.theforeman.org/issues/19169"
        },
        {
          "name": "RHSA-2018:0336",
          "tags": [
            "vendor-advisory",
            "x_refsource_REDHAT"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:0336"
        },
        {
          "name": "97526",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97526"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2672"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2017-2672",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "foreman",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "foreman 1.15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "[UNKNOWN]"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A flaw was found in foreman before version 1.15 in the logging of adding and registering images. An attacker with access to the foreman log file would be able to view passwords for provisioned systems in the log file, allowing them to access those systems."
            }
          ]
        },
        "impact": {
          "cvss": [
            [
              {
                "vectorString": "6.5/CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ]
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://projects.theforeman.org/issues/19169",
              "refsource": "CONFIRM",
              "url": "https://projects.theforeman.org/issues/19169"
            },
            {
              "name": "RHSA-2018:0336",
              "refsource": "REDHAT",
              "url": "https://access.redhat.com/errata/RHSA-2018:0336"
            },
            {
              "name": "97526",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97526"
            },
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2672",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2672"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2017-2672",
    "datePublished": "2018-06-21T13:00:00.000Z",
    "dateReserved": "2016-12-01T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:02:07.221Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-8366 (GCVE-0-2016-8366)

Vulnerability from cvelistv5 – Published: 2018-04-05 16:00 – Updated: 2024-09-16 21:08
VLAI
Summary
Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
References
Impacted products
Date Public
2016-11-08 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T02:20:30.995Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-313-01"
          },
          {
            "name": "45586",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/45586/"
          },
          {
            "name": "94163",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/94163"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Phoenix Contact ILC PLCs",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "status": "affected",
              "version": "All ILC 1xx PLCs"
            }
          ]
        }
      ],
      "datePublic": "2016-11-08T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-13T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-313-01"
        },
        {
          "name": "45586",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/45586/"
        },
        {
          "name": "94163",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/94163"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2016-11-08T00:00:00",
          "ID": "CVE-2016-8366",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Phoenix Contact ILC PLCs",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All ILC 1xx PLCs"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Phoenix Contact"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-313-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-313-01"
            },
            {
              "name": "45586",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/45586/"
            },
            {
              "name": "94163",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/94163"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2016-8366",
    "datePublished": "2018-04-05T16:00:00.000Z",
    "dateReserved": "2016-09-28T00:00:00.000Z",
    "dateUpdated": "2024-09-16T21:08:54.504Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-3952 (GCVE-0-2015-3952)

Vulnerability from cvelistv5 – Published: 2019-03-25 15:42 – Updated: 2024-08-06 06:04
VLAI
Summary
Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext storage of sensitive information CWE-312
References
Date Public
2015-06-10 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:04:01.121Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-161-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Plum A+ Infusion System",
          "vendor": "Hospira",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c= 13.4"
            }
          ]
        },
        {
          "product": "Plum A+3 Infusion System",
          "vendor": "Hospira",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c= 13.6"
            }
          ]
        },
        {
          "product": "Symbiq Infusion System",
          "vendor": "Hospira",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c= 3.13"
            }
          ]
        }
      ],
      "datePublic": "2015-06-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "Cleartext storage of sensitive information CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-25T15:42:39.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-161-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2015-3952",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Plum A+ Infusion System",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c= 13.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Plum A+3 Infusion System",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c= 13.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Symbiq Infusion System",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c= 3.13"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hospira"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Wireless keys are stored in plain text on Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext storage of sensitive information CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-161-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-161-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2015-3952",
    "datePublished": "2019-03-25T15:42:39.000Z",
    "dateReserved": "2015-05-12T00:00:00.000Z",
    "dateUpdated": "2024-08-06T06:04:01.121Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-1012 (GCVE-0-2015-1012)

Vulnerability from cvelistv5 – Published: 2019-03-25 18:20 – Updated: 2024-08-06 04:26
VLAI
Summary
Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless capacity in a clinical setting. Hospira has developed a new version of the PCS Infusion System, version 7.0 that addresses the identified vulnerabilities. Version 7.0 has Port 20/FTP and Port 23/TELNET closed by default to prevent unauthorized access.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext storage of sensitive information CWE-312
References
Impacted products
Date Public
2015-05-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T04:26:11.620Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-125-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LifeCare PCA Infusion System",
          "vendor": "Hospira",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c= 5.0"
            }
          ]
        }
      ],
      "datePublic": "2015-05-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless capacity in a clinical setting. Hospira has developed a new version of the PCS Infusion System, version 7.0 that addresses the identified vulnerabilities. Version 7.0 has Port 20/FTP and Port 23/TELNET closed by default to prevent unauthorized access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "Cleartext storage of sensitive information CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-25T18:20:12.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-125-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2015-1012",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LifeCare PCA Infusion System",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c= 5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hospira"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless capacity in a clinical setting. Hospira has developed a new version of the PCS Infusion System, version 7.0 that addresses the identified vulnerabilities. Version 7.0 has Port 20/FTP and Port 23/TELNET closed by default to prevent unauthorized access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext storage of sensitive information CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-125-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-125-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2015-1012",
    "datePublished": "2019-03-25T18:20:12.000Z",
    "dateReserved": "2015-01-10T00:00:00.000Z",
    "dateUpdated": "2024-08-06T04:26:11.620Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-5433 (GCVE-0-2014-5433)

Vulnerability from cvelistv5 – Published: 2019-03-26 15:07 – Updated: 2024-08-06 11:41
VLAI
Summary
An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext storage of sensitive information CWE-312
References
Impacted products
Vendor Product Version
Baxter SIGMA Spectrum Infusion System Affected: 6.05 (model 35700BAX) with wireless battery module (WBM) version 16
Create a notification for this product.
Date Public
2015-06-30 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.305Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIGMA Spectrum Infusion System",
          "vendor": "Baxter",
          "versions": [
            {
              "status": "affected",
              "version": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
            }
          ]
        }
      ],
      "datePublic": "2015-06-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "Cleartext storage of sensitive information CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-26T15:07:39.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5433",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIGMA Spectrum Infusion System",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.05 (model 35700BAX) with wireless battery module (WBM) version 16"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Baxter"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16, which may allow an attacker to gain access the host network. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext storage of sensitive information CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-181-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5433",
    "datePublished": "2019-03-26T15:07:39.000Z",
    "dateReserved": "2014-08-22T00:00:00.000Z",
    "dateUpdated": "2024-08-06T11:41:49.305Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

GHSA-2289-X8CM-QHF2

Vulnerability from github – Published: 2026-08-20 00:35 – Updated: 2026-08-20 00:35
VLAI
Details

In versions below 3.8.5 of the Phantom app for Splunk SOAR, a user who holds a role with permission to run actions could expose a sensitive archive password by invoking the deflate item action, because the action's password parameter is not masked and is shown in cleartext in the user interface. The information disclosure is possible because the app does not mark the affected action parameter as a password. For more information see Run an action in Splunk SOAR (https://help.splunk.com/en/splunk-soar/soar-on-premises/use-splunk-soar-on-premises/8.6.0/use-the-command-line-interface-to-perform-tasks-in-splunk-soar-on-premises/run-an-action-in-splunk-soar-on-premises).

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2026-76382"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-312"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2026-08-19T22:17:24Z",
    "severity": "MODERATE"
  },
  "details": "In versions below 3.8.5 of the Phantom app for Splunk SOAR, a user who holds a role with permission to run actions could expose a sensitive archive password by invoking the deflate item action, because the action\u0027s password parameter is not masked and is shown in cleartext in the user interface. The information disclosure is possible because the app does not mark the affected action parameter as a password. For more information see Run an action in Splunk SOAR (https://help.splunk.com/en/splunk-soar/soar-on-premises/use-splunk-soar-on-premises/8.6.0/use-the-command-line-interface-to-perform-tasks-in-splunk-soar-on-premises/run-an-action-in-splunk-soar-on-premises).",
  "id": "GHSA-2289-x8cm-qhf2",
  "modified": "2026-08-20T00:35:04Z",
  "published": "2026-08-20T00:35:04Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-76382"
    },
    {
      "type": "WEB",
      "url": "https://advisory.splunk.com/advisories/SVD-2026-0806"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-22WJ-VF5F-WRVJ

Vulnerability from github – Published: 2022-11-23 21:30 – Updated: 2024-07-03 17:59
VLAI
Summary
Password exposure in H2 Database
Details

The web-based admin console in H2 Database Engine through 2.1.214 can be started via the CLI with the argument -webAdminPassword, which allows the user to specify the password in cleartext for the web admin console. Consequently, a local user (or an attacker that has obtained local access through some means) would be able to discover the password by listing processes and their arguments. NOTE: the vendor states "This is not a vulnerability of H2 Console ... Passwords should never be passed on the command line and every qualified DBA or system administrator is expected to know that."

Show details on source website

{
  "affected": [
    {
      "package": {
        "ecosystem": "Maven",
        "name": "com.h2database:h2"
      },
      "ranges": [
        {
          "events": [
            {
              "introduced": "1.4.198"
            },
            {
              "fixed": "2.2.220"
            }
          ],
          "type": "ECOSYSTEM"
        }
      ]
    }
  ],
  "aliases": [
    "CVE-2022-45868"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-200",
      "CWE-312"
    ],
    "github_reviewed": true,
    "github_reviewed_at": "2022-11-23T22:31:05Z",
    "nvd_published_at": "2022-11-23T21:15:00Z",
    "severity": "HIGH"
  },
  "details": "The web-based admin console in H2 Database Engine through 2.1.214 can be started via the CLI with the argument -webAdminPassword, which allows the user to specify the password in cleartext for the web admin console. Consequently, a local user (or an attacker that has obtained local access through some means) would be able to discover the password by listing processes and their arguments. NOTE: the vendor states \"This is not a vulnerability of H2 Console ... Passwords should never be passed on the command line and every qualified DBA or system administrator is expected to know that.\"",
  "id": "GHSA-22wj-vf5f-wrvj",
  "modified": "2024-07-03T17:59:02Z",
  "published": "2022-11-23T21:30:31Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-45868"
    },
    {
      "type": "WEB",
      "url": "https://github.com/h2database/h2database/issues/3686"
    },
    {
      "type": "WEB",
      "url": "https://github.com/h2database/h2database/pull/3833"
    },
    {
      "type": "WEB",
      "url": "https://github.com/h2database/h2database/commit/581ed18ff9d6b3761d851620ed88a3994a351a0d"
    },
    {
      "type": "ADVISORY",
      "url": "https://github.com/advisories/GHSA-22wj-vf5f-wrvj"
    },
    {
      "type": "PACKAGE",
      "url": "https://github.com/h2database/h2database"
    },
    {
      "type": "WEB",
      "url": "https://github.com/h2database/h2database/blob/96832bf5a97cdc0adc1f2066ed61c54990d66ab5/h2/src/main/org/h2/server/web/WebServer.java#L346-L347"
    },
    {
      "type": "WEB",
      "url": "https://github.com/h2database/h2database/releases/tag/version-2.2.220"
    },
    {
      "type": "WEB",
      "url": "https://sites.google.com/sonatype.com/vulnerabilities/sonatype-2022-6243"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
      "type": "CVSS_V3"
    }
  ],
  "summary": "Password exposure in H2 Database "
}

Mitigation
Implementation System Configuration Operation

When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to encrypt the data at rest. [REF-1297] [REF-1299] [REF-1301]

Mitigation
Implementation System Configuration Operation

In some systems/environments such as cloud, the use of "double encryption" (at both the software and hardware layer) might be required, and the developer might be solely responsible for both layers, instead of shared responsibility with the administrator of the broader system/environment.

CAPEC-37: Retrieve Embedded Sensitive Data

An attacker examines a target system to find sensitive data that has been embedded within it. This information can reveal confidential contents, such as account numbers or individual keys/credentials that can be used as an intermediate step in a larger attack.