Common Weakness Enumeration

CWE-284

Discouraged

Improper Access Control

Abstraction: Pillar · Status: Incomplete

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

10687 vulnerabilities reference this CWE, most recent first.

CVE-2022-24309 (GCVE-0-2022-24309)

Vulnerability from cvelistv5 – Published: 2022-03-08 11:31 – Updated: 2024-10-08 08:39
VLAI
Summary
A vulnerability has been identified in Mendix Runtime V7 (All versions < V7.23.29), Mendix Runtime V8 (All versions < V8.18.16), Mendix Runtime V9 (All versions < V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data.
CWE
  • CWE-284 - Improper Access Control
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.516Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.23.29",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V8",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.18.16",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Runtime V9",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Mendix Runtime V7 (All versions \u003c V7.23.29), Mendix Runtime V8 (All versions \u003c V8.18.16), Mendix Runtime V9 (All versions \u003c V9.13 only with Runtime Custom Setting *DataStorage.UseNewQueryHandler* set to False). If an entity has an association readable by the user, then in some cases, Mendix Runtime may not apply checks for XPath constraints that parse said associations, within apps running on affected versions. A malicious user could use this to dump and manipulate sensitive data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-08T08:39:51.939Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148641.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-24309",
    "datePublished": "2022-03-08T11:31:29.000Z",
    "dateReserved": "2022-02-02T00:00:00.000Z",
    "dateUpdated": "2024-10-08T08:39:51.939Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24038 (GCVE-0-2022-24038)

Vulnerability from cvelistv5 – Published: 2022-11-18 08:45 – Updated: 2026-05-20 07:37
VLAI
Title
Unauthorized modification in Karmasis Informatics Infraskope SIEM+
Summary
Karmasis Informatics Infraskope SIEM+ has an unauthenticated access vulnerability which could allow an unauthenticated attacker to damage the page where the agents are listed.
CWE
  • CWE-284 - Improper Access Control
References
Impacted products
Vendor Product Version
Karmasis Informatics Infraskope SIEM+ Affected: 0 , < 7.10.xx (custom)
Create a notification for this product.
Date Public
2022-11-17 21:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:59:23.629Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.usom.gov.tr/bildirim/tr-22-0691"
          },
          {
            "tags": [
              "product",
              "x_transferred"
            ],
            "url": "https://karmasis.com/urunlerimiz/infraskope-siem/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Infraskope SIEM+",
          "vendor": "Karmasis Informatics",
          "versions": [
            {
              "lessThan": "7.10.xx",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Gokhan SAHIN"
        }
      ],
      "datePublic": "2022-11-17T21:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\n\nKarmasis Informatics Infraskope SIEM+\n\nhas an unauthenticated access vulnerability which could allow an unauthenticated attacker to damage the page where the agents are listed.\u003c/p\u003e"
            }
          ],
          "value": "Karmasis Informatics Infraskope SIEM+\n\nhas an unauthenticated access vulnerability which could allow an unauthenticated attacker to damage the page where the agents are listed."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-153",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-153 Input Data Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-20T07:37:21.909Z",
        "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "shortName": "TR-CERT"
      },
      "references": [
        {
          "tags": [
            "government-resource",
            "broken-link"
          ],
          "url": "https://www.usom.gov.tr/bildirim/tr-22-0691"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://karmasis.com/urunlerimiz/infraskope-siem/"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-22-0691"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\n\nUpdate the Karmasis Informatics Infraskope SIEM+ software to \u0026gt;= 7.10.xx.\n\n \u003c/p\u003e"
            }
          ],
          "value": "Update the Karmasis Informatics Infraskope SIEM+ software to \u003e= 7.10.xx."
        }
      ],
      "source": {
        "advisory": "TR-22-0691",
        "defect": [
          "TR-22-0691"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Unauthorized modification in Karmasis Informatics Infraskope SIEM+",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
    "assignerShortName": "TR-CERT",
    "cveId": "CVE-2022-24038",
    "datePublished": "2022-11-18T08:45:17.726Z",
    "dateReserved": "2022-01-27T00:00:00.000Z",
    "dateUpdated": "2026-05-20T07:37:21.909Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2022-24036 (GCVE-0-2022-24036)

Vulnerability from cvelistv5 – Published: 2022-11-16 12:05 – Updated: 2026-05-20 07:38
VLAI
Title
Unauthorized modification in Karmasis Informatics Infraskope SIEM+
Summary
Karmasis Informatics Infraskope SIEM+ has an unauthenticated access vulnerability which could allow an unauthenticated attacker to modificate logs.
CWE
  • CWE-284 - Improper Access Control
References
Impacted products
Vendor Product Version
Karmasis Informatics Infraskope SIEM+ Affected: 0 , < 7.10.xx (custom)
Create a notification for this product.
Date Public
2022-11-15 21:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:59:23.635Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.usom.gov.tr/bildirim/tr-22-0691"
          },
          {
            "tags": [
              "product",
              "x_transferred"
            ],
            "url": "https://karmasis.com/urunlerimiz/infraskope-siem/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Infraskope SIEM+",
          "vendor": "Karmasis Informatics",
          "versions": [
            {
              "lessThan": "7.10.xx",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Gokhan SAHIN"
        }
      ],
      "datePublic": "2022-11-15T21:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eKarmasis Informatics Infraskope SIEM+ has an unauthenticated access vulnerability which could allow an unauthenticated attacker to modificate logs.\u003c/p\u003e"
            }
          ],
          "value": "Karmasis Informatics Infraskope SIEM+ has an unauthenticated access vulnerability which could allow an unauthenticated attacker to modificate logs."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-268",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-268 Audit Log Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-20T07:38:27.109Z",
        "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "shortName": "TR-CERT"
      },
      "references": [
        {
          "tags": [
            "government-resource",
            "broken-link"
          ],
          "url": "https://www.usom.gov.tr/bildirim/tr-22-0691"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://karmasis.com/urunlerimiz/infraskope-siem/"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-22-0691"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eUpdate the Karmasis Informatics Infraskope SIEM+ software to \u0026gt;= 7.10.xx. \u003c/p\u003e"
            }
          ],
          "value": "Update the Karmasis Informatics Infraskope SIEM+ software to \u003e= 7.10.xx."
        }
      ],
      "source": {
        "advisory": "TR-22-0691",
        "defect": [
          "TR-22-0691"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Unauthorized modification in Karmasis Informatics Infraskope SIEM+",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
    "assignerShortName": "TR-CERT",
    "cveId": "CVE-2022-24036",
    "datePublished": "2022-11-16T12:05:11.824Z",
    "dateReserved": "2022-01-27T00:00:00.000Z",
    "dateUpdated": "2026-05-20T07:38:27.109Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2022-23997 (GCVE-0-2022-23997)

Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2024-08-03 03:59
VLAI
Summary
Unprotected component vulnerability in StTheaterModeDurationAlarmReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to disable theater mode without a proper permission.
CWE
  • CWE-284 - Improper Access Control
References
Impacted products
Vendor Product Version
Samsung Mobile Samsung Wearable Devices Affected: Wear OS 3.0 , < Firmware update Feb-2022 Release (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:59:23.316Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Samsung Wearable Devices",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "Firmware update Feb-2022 Release",
              "status": "affected",
              "version": "Wear OS 3.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unprotected component vulnerability in StTheaterModeDurationAlarmReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to disable theater mode without a proper permission."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-11T17:40:18.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2022-23997",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Samsung Wearable Devices",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Wear OS 3.0",
                            "version_value": "Firmware update Feb-2022 Release"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unprotected component vulnerability in StTheaterModeDurationAlarmReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to disable theater mode without a proper permission."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2022-23997",
    "datePublished": "2022-02-11T17:40:18.000Z",
    "dateReserved": "2022-01-26T00:00:00.000Z",
    "dateUpdated": "2024-08-03T03:59:23.316Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-23996 (GCVE-0-2022-23996)

Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2024-08-03 03:59
VLAI
Summary
Unprotected component vulnerability in StTheaterModeReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to enable bedtime mode without a proper permission.
CWE
  • CWE-284 - Improper Access Control
References
Impacted products
Vendor Product Version
Samsung Mobile Samsung Wearable Devices Affected: Wear OS 3.0 , < Firmware update Feb-2022 Release (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:59:23.190Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Samsung Wearable Devices",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "Firmware update Feb-2022 Release",
              "status": "affected",
              "version": "Wear OS 3.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unprotected component vulnerability in StTheaterModeReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to enable bedtime mode without a proper permission."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-11T17:40:17.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2022-23996",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Samsung Wearable Devices",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Wear OS 3.0",
                            "version_value": "Firmware update Feb-2022 Release"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unprotected component vulnerability in StTheaterModeReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to enable bedtime mode without a proper permission."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2022-23996",
    "datePublished": "2022-02-11T17:40:17.000Z",
    "dateReserved": "2022-01-26T00:00:00.000Z",
    "dateUpdated": "2024-08-03T03:59:23.190Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-23995 (GCVE-0-2022-23995)

Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2024-08-03 03:59
VLAI
Summary
Unprotected component vulnerability in StBedtimeModeAlarmReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to change bedtime mode without a proper permission.
CWE
  • CWE-284 - Improper Access Control
References
Impacted products
Vendor Product Version
Samsung Mobile Samsung Wearable Devices Affected: Wear OS 3.0 , < Firmware update Feb-2022 Release (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:59:23.330Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Samsung Wearable Devices",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "Firmware update Feb-2022 Release",
              "status": "affected",
              "version": "Wear OS 3.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Unprotected component vulnerability in StBedtimeModeAlarmReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to change bedtime mode without a proper permission."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-11T17:40:16.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2022-23995",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Samsung Wearable Devices",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Wear OS 3.0",
                            "version_value": "Firmware update Feb-2022 Release"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unprotected component vulnerability in StBedtimeModeAlarmReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to change bedtime mode without a proper permission."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2022-23995",
    "datePublished": "2022-02-11T17:40:16.000Z",
    "dateReserved": "2022-01-26T00:00:00.000Z",
    "dateUpdated": "2024-08-03T03:59:23.330Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-23994 (GCVE-0-2022-23994)

Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2024-08-03 03:59
VLAI
Summary
An Improper access control vulnerability in StBedtimeModeReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to change bedtime mode without a proper permission.
CWE
  • CWE-284 - Improper Access Control
References
Impacted products
Vendor Product Version
Samsung Mobile Samsung Wearable Devices Affected: Wear OS 3.0 , < Firmware update Feb-2022 Release (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:59:23.288Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Samsung Wearable Devices",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "Firmware update Feb-2022 Release",
              "status": "affected",
              "version": "Wear OS 3.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper access control vulnerability in StBedtimeModeReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to change bedtime mode without a proper permission."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-11T17:40:16.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2022-23994",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Samsung Wearable Devices",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Wear OS 3.0",
                            "version_value": "Firmware update Feb-2022 Release"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper access control vulnerability in StBedtimeModeReceiver in Wear OS 3.0 prior to Firmware update Feb-2022 Release allows untrusted applications to change bedtime mode without a proper permission."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=2"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2022-23994",
    "datePublished": "2022-02-11T17:40:16.000Z",
    "dateReserved": "2022-01-26T00:00:00.000Z",
    "dateUpdated": "2024-08-03T03:59:23.288Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-23981 (GCVE-0-2022-23981)

Vulnerability from cvelistv5 – Published: 2022-02-18 17:50 – Updated: 2026-04-28 16:07
VLAI
Title
WordPress Perfect Brands for WooCommerce plugin <= 2.0.4 - Set Featured Brand vulnerability
Summary
The vulnerability allows Subscriber+ level users to create brands in WordPress Perfect Brands for WooCommerce plugin (versions <= 2.0.4).
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-20 19:33 UTC
CWE
  • CWE-284 - Improper Access Control
References
Impacted products
Date Public
2022-01-28 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:59:23.330Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://wordpress.org/plugins/perfect-woocommerce-brands/#developers"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://patchstack.com/database/vulnerability/perfect-woocommerce-brands/wordpress-perfect-brands-for-woocommerce-plugin-2-0-4-subscriber-set-featured-brand-vulnerability"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-23981",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-20T19:33:17.579473Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-20T20:31:37.130Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Perfect Brands for WooCommerce (WordPress plugin)",
          "vendor": "QuadLayers",
          "versions": [
            {
              "lessThanOrEqual": "2.0.4",
              "status": "affected",
              "version": "\u003c= 2.0.4",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Vulnerability discovered by Dave Jong (Patchstack)."
        }
      ],
      "datePublic": "2022-01-28T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The vulnerability allows Subscriber+ level users to create brands in WordPress Perfect Brands for WooCommerce plugin (versions \u003c= 2.0.4)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-28T16:07:38.724Z",
        "orgId": "21595511-bba5-4825-b968-b78d1f9984a3",
        "shortName": "Patchstack"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://wordpress.org/plugins/perfect-woocommerce-brands/#developers"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://patchstack.com/database/vulnerability/perfect-woocommerce-brands/wordpress-perfect-brands-for-woocommerce-plugin-2-0-4-subscriber-set-featured-brand-vulnerability"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update to 2.0.5 or higher version."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "WordPress Perfect Brands for WooCommerce plugin \u003c= 2.0.4 - Set Featured Brand vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "audit@patchstack.com",
          "DATE_PUBLIC": "2022-01-28T09:32:00.000Z",
          "ID": "CVE-2022-23981",
          "STATE": "PUBLIC",
          "TITLE": "WordPress Perfect Brands for WooCommerce plugin \u003c= 2.0.4 - Set Featured Brand vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Perfect Brands for WooCommerce (WordPress plugin)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "\u003c= 2.0.4",
                            "version_value": "2.0.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "QuadLayers"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Vulnerability discovered by Dave Jong (Patchstack)."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The vulnerability allows Subscriber+ level users to create brands in WordPress Perfect Brands for WooCommerce plugin (versions \u003c= 2.0.4)."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://wordpress.org/plugins/perfect-woocommerce-brands/#developers",
              "refsource": "CONFIRM",
              "url": "https://wordpress.org/plugins/perfect-woocommerce-brands/#developers"
            },
            {
              "name": "https://patchstack.com/database/vulnerability/perfect-woocommerce-brands/wordpress-perfect-brands-for-woocommerce-plugin-2-0-4-subscriber-set-featured-brand-vulnerability",
              "refsource": "CONFIRM",
              "url": "https://patchstack.com/database/vulnerability/perfect-woocommerce-brands/wordpress-perfect-brands-for-woocommerce-plugin-2-0-4-subscriber-set-featured-brand-vulnerability"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update to 2.0.5 or higher version."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "21595511-bba5-4825-b968-b78d1f9984a3",
    "assignerShortName": "Patchstack",
    "cveId": "CVE-2022-23981",
    "datePublished": "2022-02-18T17:50:14.146Z",
    "dateReserved": "2022-01-26T00:00:00.000Z",
    "dateUpdated": "2026-04-28T16:07:38.724Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2022-23768 (GCVE-0-2022-23768)

Vulnerability from cvelistv5 – Published: 2022-09-19 19:48 – Updated: 2025-06-03 18:20
VLAI
Title
Neo Information Sys. NIS-HAP11AC remote access and manipulation vulnerability
Summary
This Vulnerability in NIS-HAP11AC is caused by an exposed external port for the telnet service. Remote attackers use this vulnerability to induce all attacks such as source code hijacking, remote control of the device.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-29 18:33 UTC
CWE
  • CWE-284 - Improper Access Control
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:51:45.956Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66928"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-23768",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-29T18:33:04.372892Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-03T18:20:38.436Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "Windows, Android and etc."
          ],
          "product": "Home AP NIS-HAP11AC",
          "vendor": "Neo Information Systems Co., Ltd",
          "versions": [
            {
              "status": "affected",
              "version": "V3.0-B20201117095902"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This Vulnerability in NIS-HAP11AC is caused by an exposed external port for the telnet service. Remote attackers use this vulnerability to induce all attacks such as source code hijacking, remote control of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-19T19:48:56.000Z",
        "orgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
        "shortName": "krcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66928"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Neo Information Sys. NIS-HAP11AC remote access and manipulation vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vuln@krcert.or.kr",
          "ID": "CVE-2022-23768",
          "STATE": "PUBLIC",
          "TITLE": "Neo Information Sys. NIS-HAP11AC remote access and manipulation vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Home AP NIS-HAP11AC",
                      "version": {
                        "version_data": [
                          {
                            "platform": "Windows, Android and etc.",
                            "version_affected": "=",
                            "version_value": "V3.0-B20201117095902"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Neo Information Systems Co., Ltd"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This Vulnerability in NIS-HAP11AC is caused by an exposed external port for the telnet service. Remote attackers use this vulnerability to induce all attacks such as source code hijacking, remote control of the device."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66928",
              "refsource": "MISC",
              "url": "https://www.krcert.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=66928"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
    "assignerShortName": "krcert",
    "cveId": "CVE-2022-23768",
    "datePublished": "2022-09-19T19:48:57.000Z",
    "dateReserved": "2022-01-19T00:00:00.000Z",
    "dateUpdated": "2025-06-03T18:20:38.436Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-23730 (GCVE-0-2022-23730)

Vulnerability from cvelistv5 – Published: 2022-03-11 17:54 – Updated: 2024-08-03 03:51
VLAI
Summary
The public API error causes for the attacker to be able to bypass API access control.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
References
URL Tags
https://lgsecurity.lge.com/bulletins/tv x_refsource_MISC
Impacted products
Vendor Product Version
n/a LG webOS TV Affected: webOS 4.0 or higher
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:51:46.129Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://lgsecurity.lge.com/bulletins/tv"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LG webOS TV",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "webOS 4.0 or higher"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The public API error causes for the attacker to be able to bypass API access control."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-11T17:54:10.000Z",
        "orgId": "42f21055-226c-4bce-a3c8-ecf55a3551fb",
        "shortName": "LGE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://lgsecurity.lge.com/bulletins/tv"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "product.security@lge.com",
          "ID": "CVE-2022-23730",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LG webOS TV",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "webOS 4.0 or higher"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The public API error causes for the attacker to be able to bypass API access control."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://lgsecurity.lge.com/bulletins/tv",
              "refsource": "MISC",
              "url": "https://lgsecurity.lge.com/bulletins/tv"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "42f21055-226c-4bce-a3c8-ecf55a3551fb",
    "assignerShortName": "LGE",
    "cveId": "CVE-2022-23730",
    "datePublished": "2022-03-11T17:54:10.000Z",
    "dateReserved": "2022-01-19T00:00:00.000Z",
    "dateUpdated": "2024-08-03T03:51:46.129Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation MIT-1
Architecture and Design Operation

Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.

Mitigation MIT-46
Architecture and Design

Strategy: Separation of Privilege

  • Compartmentalize the system to have "safe" areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
  • Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
CAPEC-19: Embedding Scripts within Scripts

An adversary leverages the capability to execute their own script by embedding it within other scripts that the target software is likely to execute due to programs' vulnerabilities that are brought on by allowing remote hosts to execute scripts.

CAPEC-441: Malicious Logic Insertion

An adversary installs or adds malicious logic (also known as malware) into a seemingly benign component of a fielded system. This logic is often hidden from the user of the system and works behind the scenes to achieve negative impacts. With the proliferation of mass digital storage and inexpensive multimedia devices, Bluetooth and 802.11 support, new attack vectors for spreading malware are emerging for things we once thought of as innocuous greeting cards, picture frames, or digital projectors. This pattern of attack focuses on systems already fielded and used in operation as opposed to systems and their components that are still under development and part of the supply chain.

CAPEC-478: Modification of Windows Service Configuration

An adversary exploits a weakness in access control to modify the execution parameters of a Windows service. The goal of this attack is to execute a malicious binary in place of an existing service.

CAPEC-479: Malicious Root Certificate

An adversary exploits a weakness in authorization and installs a new root certificate on a compromised system. Certificates are commonly used for establishing secure TLS/SSL communications within a web browser. When a user attempts to browse a website that presents a certificate that is not trusted an error message will be displayed to warn the user of the security risk. Depending on the security settings, the browser may not allow the user to establish a connection to the website. Adversaries have used this technique to avoid security warnings prompting users when compromised systems connect over HTTPS to adversary controlled web servers that spoof legitimate websites in order to collect login credentials.

CAPEC-502: Intent Spoof

An adversary, through a previously installed malicious application, issues an intent directed toward a specific trusted application's component in an attempt to achieve a variety of different objectives including modification of data, information disclosure, and data injection. Components that have been unintentionally exported and made public are subject to this type of an attack. If the component trusts the intent's action without verififcation, then the target application performs the functionality at the adversary's request, helping the adversary achieve the desired negative technical impact.

CAPEC-503: WebView Exposure

An adversary, through a malicious web page, accesses application specific functionality by leveraging interfaces registered through WebView's addJavascriptInterface API. Once an interface is registered to WebView through addJavascriptInterface, it becomes global and all pages loaded in the WebView can call this interface.

CAPEC-536: Data Injected During Configuration

An attacker with access to data files and processes on a victim's system injects malicious data into critical operational data during configuration or recalibration, causing the victim's system to perform in a suboptimal manner that benefits the adversary.

CAPEC-546: Incomplete Data Deletion in a Multi-Tenant Environment

An adversary obtains unauthorized information due to insecure or incomplete data deletion in a multi-tenant environment. If a cloud provider fails to completely delete storage and data from former cloud tenants' systems/resources, once these resources are allocated to new, potentially malicious tenants, the latter can probe the provided resources for sensitive information still there.

CAPEC-550: Install New Service

When an operating system starts, it also starts programs called services or daemons. Adversaries may install a new service which will be executed at startup (on a Windows system, by modifying the registry). The service name may be disguised by using a name from a related operating system or benign software. Services are usually run with elevated privileges.

CAPEC-551: Modify Existing Service

When an operating system starts, it also starts programs called services or daemons. Modifying existing services may break existing services or may enable services that are disabled/not commonly used.

CAPEC-552: Install Rootkit

An adversary exploits a weakness in authentication to install malware that alters the functionality and information provide by targeted operating system API calls. Often referred to as rootkits, it is often used to hide the presence of programs, files, network connections, services, drivers, and other system components.

CAPEC-556: Replace File Extension Handlers

When a file is opened, its file handler is checked to determine which program opens the file. File handlers are configuration properties of many operating systems. Applications can modify the file handler for a given file extension to call an arbitrary program when a file with the given extension is opened.

CAPEC-558: Replace Trusted Executable

An adversary exploits weaknesses in privilege management or access control to replace a trusted executable with a malicious version and enable the execution of malware when that trusted executable is called.

CAPEC-562: Modify Shared File

An adversary manipulates the files in a shared location by adding malicious programs, scripts, or exploit code to valid content. Once a user opens the shared content, the tainted content is executed.

CAPEC-563: Add Malicious File to Shared Webroot

An adversaries may add malicious content to a website through the open file share and then browse to that content with a web browser to cause the server to execute the content. The malicious content will typically run under the context and permissions of the web server process, often resulting in local system or administrative privileges depending on how the web server is configured.

CAPEC-564: Run Software at Logon

Operating system allows logon scripts to be run whenever a specific user or users logon to a system. If adversaries can access these scripts, they may insert additional code into the logon script. This code can allow them to maintain persistence or move laterally within an enclave because it is executed every time the affected user or users logon to a computer. Modifying logon scripts can effectively bypass workstation and enclave firewalls. Depending on the access configuration of the logon scripts, either local credentials or a remote administrative account may be necessary.

CAPEC-578: Disable Security Software

An adversary exploits a weakness in access control to disable security tools so that detection does not occur. This can take the form of killing processes, deleting registry keys so that tools do not start at run time, deleting log files, or other methods.