CWE-280
AllowedImproper Handling of Insufficient Permissions or Privileges
Abstraction: Base · Status: Draft
The product does not handle or incorrectly handles when it has insufficient privileges to access resources or functionality as specified by their permissions. This may cause it to follow unexpected code paths that may leave the product in an invalid state.
293 vulnerabilities reference this CWE, most recent first.
CVE-2021-37851 (GCVE-0-2021-37851)
Vulnerability from cvelistv5 – Published: 2022-05-11 14:08 – Updated: 2024-09-16 22:51- CWE-280 - Improper Handling of Insufficient Permissions or Privileges
| URL | Tags |
|---|---|
| https://support.eset.com/en/ca8268 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| ESET, spol. s r.o. | ESET NOD32 Antivirus |
Affected:
11.2 , < 15.1.12.0
(custom)
|
|
| ESET, spol. s r.o. | ESET Internet Security |
Affected:
11.2 , < 15.1.12.0
(custom)
|
|
| ESET, spol. s r.o. | ESET Smart Security Premium |
Affected:
11.2 , < 15.1.12.0
(custom)
|
|
| ESET, spol. s r.o. | ESET Endpoint Antivirus |
Affected:
6.0 , < 9.0.2046.0
(custom)
|
|
| ESET, spol. s r.o. | ESET Endpoint Security |
Affected:
6.0 , < 9.0.2046.0
(custom)
|
|
| ESET, spol. s r.o. | ESET Server Security for Microsoft Windows Server |
Affected:
8.0 , < 9.0.12012.0
(custom)
|
|
| ESET, spol. s r.o. | ESET File Security for Microsoft Windows Server |
Affected:
6.0 8.0.12013.0
|
|
| ESET, spol. s r.o. | ESET Mail Security for Microsoft Exchange Server |
Affected:
6.0 , < 8.0.10020.0
(custom)
|
|
| ESET, spol. s r.o. | ESET Mail Security for IBM Domino |
Affected:
6.0 , < 8.0.14011.0
(custom)
|
|
| ESET, spol. s r.o. | ESET Security for Microsoft SharePoint Server |
Affected:
6.0 , < 8.0.15009.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:30:08.493Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://support.eset.com/en/ca8268"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ESET NOD32 Antivirus",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"lessThan": "15.1.12.0",
"status": "affected",
"version": "11.2",
"versionType": "custom"
}
]
},
{
"product": "ESET Internet Security",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"lessThan": "15.1.12.0",
"status": "affected",
"version": "11.2",
"versionType": "custom"
}
]
},
{
"product": "ESET Smart Security Premium",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"lessThan": "15.1.12.0",
"status": "affected",
"version": "11.2",
"versionType": "custom"
}
]
},
{
"product": "ESET Endpoint Antivirus",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"changes": [
{
"at": "8.1.2050.0",
"status": "unaffected"
},
{
"at": "8.0.2053.0",
"status": "unaffected"
}
],
"lessThan": "9.0.2046.0",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "ESET Endpoint Security",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"changes": [
{
"at": "8.1.2050.0",
"status": "unaffected"
},
{
"at": "8.0.2053.0",
"status": "unaffected"
}
],
"lessThan": "9.0.2046.0",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "ESET Server Security for Microsoft Windows Server",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"lessThan": "9.0.12012.0",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"product": "ESET File Security for Microsoft Windows Server",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"status": "affected",
"version": "6.0 8.0.12013.0"
}
]
},
{
"product": "ESET Mail Security for Microsoft Exchange Server",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"lessThan": "8.0.10020.0",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "ESET Mail Security for IBM Domino",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"lessThan": "8.0.14011.0",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "ESET Security for Microsoft SharePoint Server",
"vendor": "ESET, spol. s r.o.",
"versions": [
{
"lessThan": "8.0.15009.0",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-05-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Local privilege escalation in Windows products of ESET allows user who is logged into the system to exploit repair feature of the installer to run malicious code with higher privileges. This issue affects: ESET, spol. s r.o. ESET NOD32 Antivirus 11.2 versions prior to 15.1.12.0. ESET, spol. s r.o. ESET Internet Security 11.2 versions prior to 15.1.12.0. ESET, spol. s r.o. ESET Smart Security Premium 11.2 versions prior to 15.1.12.0. ESET, spol. s r.o. ESET Endpoint Antivirus 6.0 versions prior to 9.0.2046.0; 6.0 versions prior to 8.1.2050.0; 6.0 versions prior to 8.0.2053.0. ESET, spol. s r.o. ESET Endpoint Security 6.0 versions prior to 9.0.2046.0; 6.0 versions prior to 8.1.2050.0; 6.0 versions prior to 8.0.2053.0. ESET, spol. s r.o. ESET Server Security for Microsoft Windows Server 8.0 versions prior to 9.0.12012.0. ESET, spol. s r.o. ESET File Security for Microsoft Windows Server 8.0.12013.0. ESET, spol. s r.o. ESET Mail Security for Microsoft Exchange Server 6.0 versions prior to 8.0.10020.0. ESET, spol. s r.o. ESET Mail Security for IBM Domino 6.0 versions prior to 8.0.14011.0. ESET, spol. s r.o. ESET Security for Microsoft SharePoint Server 6.0 versions prior to 8.0.15009.0."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "CWE-280 Improper Handling of Insufficient Permissions or Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-11T14:08:03.000Z",
"orgId": "4a9b9929-2450-4021-b7b9-469a0255b215",
"shortName": "ESET"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://support.eset.com/en/ca8268"
}
],
"source": {
"advisory": "ca8268",
"discovery": "EXTERNAL"
},
"title": "Local Privilege Escalation in ESET product for Windows",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@eset.com",
"DATE_PUBLIC": "2022-05-09T13:00:00.000Z",
"ID": "CVE-2021-37851",
"STATE": "PUBLIC",
"TITLE": "Local Privilege Escalation in ESET product for Windows"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ESET NOD32 Antivirus",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "11.2",
"version_value": "15.1.12.0"
}
]
}
},
{
"product_name": "ESET Internet Security",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "11.2",
"version_value": "15.1.12.0"
}
]
}
},
{
"product_name": "ESET Smart Security Premium",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "11.2",
"version_value": "15.1.12.0"
}
]
}
},
{
"product_name": "ESET Endpoint Antivirus",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "6.0",
"version_value": "9.0.2046.0"
},
{
"version_affected": "\u003c",
"version_name": "6.0",
"version_value": "8.1.2050.0"
},
{
"version_affected": "\u003c",
"version_name": "6.0",
"version_value": "8.0.2053.0"
}
]
}
},
{
"product_name": "ESET Endpoint Security",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "6.0",
"version_value": "9.0.2046.0"
},
{
"version_affected": "\u003c",
"version_name": "6.0",
"version_value": "8.1.2050.0"
},
{
"version_affected": "\u003c",
"version_name": "6.0",
"version_value": "8.0.2053.0"
}
]
}
},
{
"product_name": "ESET Server Security for Microsoft Windows Server",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "8.0",
"version_value": "9.0.12012.0"
}
]
}
},
{
"product_name": "ESET File Security for Microsoft Windows Server",
"version": {
"version_data": [
{
"version_name": "6.0",
"version_value": "8.0.12013.0"
}
]
}
},
{
"product_name": "ESET Mail Security for Microsoft Exchange Server",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "6.0",
"version_value": "8.0.10020.0"
}
]
}
},
{
"product_name": "ESET Mail Security for IBM Domino",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "6.0",
"version_value": "8.0.14011.0"
}
]
}
},
{
"product_name": "ESET Security for Microsoft SharePoint Server",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "6.0",
"version_value": "8.0.15009.0"
}
]
}
}
]
},
"vendor_name": "ESET, spol. s r.o."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Local privilege escalation in Windows products of ESET allows user who is logged into the system to exploit repair feature of the installer to run malicious code with higher privileges. This issue affects: ESET, spol. s r.o. ESET NOD32 Antivirus 11.2 versions prior to 15.1.12.0. ESET, spol. s r.o. ESET Internet Security 11.2 versions prior to 15.1.12.0. ESET, spol. s r.o. ESET Smart Security Premium 11.2 versions prior to 15.1.12.0. ESET, spol. s r.o. ESET Endpoint Antivirus 6.0 versions prior to 9.0.2046.0; 6.0 versions prior to 8.1.2050.0; 6.0 versions prior to 8.0.2053.0. ESET, spol. s r.o. ESET Endpoint Security 6.0 versions prior to 9.0.2046.0; 6.0 versions prior to 8.1.2050.0; 6.0 versions prior to 8.0.2053.0. ESET, spol. s r.o. ESET Server Security for Microsoft Windows Server 8.0 versions prior to 9.0.12012.0. ESET, spol. s r.o. ESET File Security for Microsoft Windows Server 8.0.12013.0. ESET, spol. s r.o. ESET Mail Security for Microsoft Exchange Server 6.0 versions prior to 8.0.10020.0. ESET, spol. s r.o. ESET Mail Security for IBM Domino 6.0 versions prior to 8.0.14011.0. ESET, spol. s r.o. ESET Security for Microsoft SharePoint Server 6.0 versions prior to 8.0.15009.0."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-280 Improper Handling of Insufficient Permissions or Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.eset.com/en/ca8268",
"refsource": "MISC",
"url": "https://support.eset.com/en/ca8268"
}
]
},
"source": {
"advisory": "ca8268",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "4a9b9929-2450-4021-b7b9-469a0255b215",
"assignerShortName": "ESET",
"cveId": "CVE-2021-37851",
"datePublished": "2022-05-11T14:08:03.466Z",
"dateReserved": "2021-08-02T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:51:23.644Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37175 (GCVE-0-2021-37175)
Vulnerability from cvelistv5 – Published: 2021-09-14 10:47 – Updated: 2024-08-04 01:16- CWE-280 - Improper Handling of Insufficient Permissions or Privileges
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM ROX MX5000 |
Affected:
All versions < V2.14.1
|
|
| Siemens | RUGGEDCOM ROX RX1400 |
Affected:
All versions < V2.14.1
|
|
| Siemens | RUGGEDCOM ROX RX1500 |
Affected:
All versions < V2.14.1
|
|
| Siemens | RUGGEDCOM ROX RX1501 |
Affected:
All versions < V2.14.1
|
|
| Siemens | RUGGEDCOM ROX RX1510 |
Affected:
All versions < V2.14.1
|
|
| Siemens | RUGGEDCOM ROX RX1511 |
Affected:
All versions < V2.14.1
|
|
| Siemens | RUGGEDCOM ROX RX1512 |
Affected:
All versions < V2.14.1
|
|
| Siemens | RUGGEDCOM ROX RX1524 |
Affected:
All versions < V2.14.1
|
|
| Siemens | RUGGEDCOM ROX RX1536 |
Affected:
All versions < V2.14.1
|
|
| Siemens | RUGGEDCOM ROX RX5000 |
Affected:
All versions < V2.14.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:16:02.802Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "RUGGEDCOM ROX MX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1400",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1500",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1501",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1510",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1511",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1512",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1524",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX1536",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
},
{
"product": "RUGGEDCOM ROX RX5000",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.14.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1400 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1500 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1501 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1510 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1511 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1512 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1524 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1536 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX5000 (All versions \u003c V2.14.1). The affected devices do not properly handle permissions to traverse the file system. If exploited, an attacker could gain access to an overview of the complete file system on the affected devices."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "CWE-280: Improper Handling of Insufficient Permissions or Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:43.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-37175",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "RUGGEDCOM ROX MX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1400",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1500",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1501",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1510",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1511",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1512",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1524",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX1536",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
},
{
"product_name": "RUGGEDCOM ROX RX5000",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.14.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1400 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1500 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1501 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1510 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1511 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1512 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1524 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX1536 (All versions \u003c V2.14.1), RUGGEDCOM ROX RX5000 (All versions \u003c V2.14.1). The affected devices do not properly handle permissions to traverse the file system. If exploited, an attacker could gain access to an overview of the complete file system on the affected devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-280: Improper Handling of Insufficient Permissions or Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-150692.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-37175",
"datePublished": "2021-09-14T10:47:43.000Z",
"dateReserved": "2021-07-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T01:16:02.802Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29031 (GCVE-0-2020-29031)
Vulnerability from cvelistv5 – Published: 2021-02-15 15:52 – Updated: 2024-08-04 16:48- CWE-280 - Improper Handling of Insufficient Permissions or Privileges
| URL | Tags |
|---|---|
| https://www.secomea.com/support/cybersecurity-adv… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Secomea | GateManager |
Affected:
All , < 9.2c
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:00.792Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2920"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.2c",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Insecure Direct Object Reference vulnerability exists in the web UI of the GateManager which allows an authenticated attacker to reset the password of any user in its domain or any sub-domain, via escalation of privileges. This issue affects all GateManager versions prior to 9.2c"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "CWE-280 Improper Handling of Insufficient Permissions or Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-15T15:52:30.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2920"
}
],
"source": {
"defect": [
"RD-2920"
],
"discovery": "EXTERNAL"
},
"title": "Insecure Direct Object Reference in GateManager WebUI can cause privilege escalation",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2020-29031",
"STATE": "PUBLIC",
"TITLE": "Insecure Direct Object Reference in GateManager WebUI can cause privilege escalation"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.2c"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Insecure Direct Object Reference vulnerability exists in the web UI of the GateManager which allows an authenticated attacker to reset the password of any user in its domain or any sub-domain, via escalation of privileges. This issue affects all GateManager versions prior to 9.2c"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-280 Improper Handling of Insufficient Permissions or Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#2920",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2920"
}
]
},
"source": {
"defect": [
"RD-2920"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29031",
"datePublished": "2021-02-15T15:52:30.000Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:00.792Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26195 (GCVE-0-2020-26195)
Vulnerability from cvelistv5 – Published: 2021-02-09 21:25 – Updated: 2024-09-16 23:55- CWE-280 - Improper Handling of Insufficient Permissions or Privileges
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00018287… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale OneFS |
Affected:
unspecified , < 8.1.2, 8.2.2, 9.0+
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:49:07.165Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000182873/dsa-2021-009-dell-powerscale-onefs-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PowerScale OneFS",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.1.2, 8.2.2, 9.0+",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-12-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC PowerScale OneFS versions 8.1.2 \u2013 9.1.0 contain an issue where the OneFS SMB directory auto-create may erroneously create a directory for a user. A remote unauthenticated attacker may take advantage of this issue to slow down the system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "CWE-280: Improper Handling of Insufficient Permissions or Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-09T21:25:21.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000182873/dsa-2021-009-dell-powerscale-onefs-security-update-for-multiple-vulnerabilities"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-12-18",
"ID": "CVE-2020-26195",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerScale OneFS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "8.1.2, 8.2.2, 9.0+"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC PowerScale OneFS versions 8.1.2 \u2013 9.1.0 contain an issue where the OneFS SMB directory auto-create may erroneously create a directory for a user. A remote unauthenticated attacker may take advantage of this issue to slow down the system."
}
]
},
"impact": {
"cvss": {
"baseScore": 5.3,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-280: Improper Handling of Insufficient Permissions or Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/en-us/000182873/dsa-2021-009-dell-powerscale-onefs-security-update-for-multiple-vulnerabilities",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/en-us/000182873/dsa-2021-009-dell-powerscale-onefs-security-update-for-multiple-vulnerabilities"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-26195",
"datePublished": "2021-02-09T21:25:22.012Z",
"dateReserved": "2020-09-30T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:55:55.907Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-10072 (GCVE-0-2020-10072)
Vulnerability from cvelistv5 – Published: 2021-05-24 21:40 – Updated: 2024-09-17 04:15- CWE-280 - Improper Handling of Insufficient Permissions or Privileges (CWE-280)
| URL | Tags |
|---|---|
| http://github.com/zephyrproject-rtos/zephyr/secur… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| zephyrproject-rtos | zephyr |
Affected:
v1.14.2 , < unspecified
(custom)
Affected: v2.2.0 , < unspecified (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T10:50:57.866Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-vf79-hqwm-w4xc"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "zephyr",
"vendor": "zephyrproject-rtos",
"versions": [
{
"lessThan": "unspecified",
"status": "affected",
"version": "v1.14.2",
"versionType": "custom"
},
{
"lessThan": "unspecified",
"status": "affected",
"version": "v2.2.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-08-28T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Improper Handling of Insufficient Permissions or Privileges in zephyr. Zephyr versions \u003e= v1.14.2, \u003e= v2.2.0 contain Improper Handling of Insufficient Permissions or Privileges (CWE-280). For more information, see https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-vf79-hqwm-w4xc"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "Improper Handling of Insufficient Permissions or Privileges (CWE-280)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-24T21:40:26.000Z",
"orgId": "e2e69745-5e70-4e92-8431-deb5529a81ad",
"shortName": "zephyr"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-vf79-hqwm-w4xc"
}
],
"source": {
"defect": [
"https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-vf79-hqwm-w4xc"
]
},
"title": "Improper Handling of Insufficient Permissions or Privileges in zephyr",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerabilities@zephyrproject.org",
"DATE_PUBLIC": "2020-08-28T00:00:00.000Z",
"ID": "CVE-2020-10072",
"STATE": "PUBLIC",
"TITLE": "Improper Handling of Insufficient Permissions or Privileges in zephyr"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "zephyr",
"version": {
"version_data": [
{
"version_affected": "\u003e=",
"version_value": "v1.14.2"
},
{
"version_affected": "\u003e=",
"version_value": "v2.2.0"
}
]
}
}
]
},
"vendor_name": "zephyrproject-rtos"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Handling of Insufficient Permissions or Privileges in zephyr. Zephyr versions \u003e= v1.14.2, \u003e= v2.2.0 contain Improper Handling of Insufficient Permissions or Privileges (CWE-280). For more information, see https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-vf79-hqwm-w4xc"
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 5.9,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.9,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Handling of Insufficient Permissions or Privileges (CWE-280)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-vf79-hqwm-w4xc",
"refsource": "MISC",
"url": "http://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-vf79-hqwm-w4xc"
}
]
},
"source": {
"defect": [
"https://github.com/zephyrproject-rtos/zephyr/security/advisories/GHSA-vf79-hqwm-w4xc"
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e2e69745-5e70-4e92-8431-deb5529a81ad",
"assignerShortName": "zephyr",
"cveId": "CVE-2020-10072",
"datePublished": "2021-05-24T21:40:26.107Z",
"dateReserved": "2020-03-04T00:00:00.000Z",
"dateUpdated": "2024-09-17T04:15:01.100Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8219 (GCVE-0-2020-8219)
Vulnerability from cvelistv5 – Published: 2020-07-30 12:53 – Updated: 2024-08-04 09:56- CWE-280 - Improper Handling of Insufficient Permissions or Privileges (CWE-280)
| URL | Tags |
|---|---|
| https://kb.pulsesecure.net/articles/Pulse_Securit… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Pulse Connect Secure |
Affected:
Fixed in 9.1R8
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:56:27.612Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44516"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Pulse Connect Secure",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Fixed in 9.1R8"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An insufficient permission check vulnerability exists in Pulse Connect Secure \u003c9.1R8 that allows an attacker to change the password of a full administrator."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "Improper Handling of Insufficient Permissions or Privileges (CWE-280)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-30T12:53:02.000Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44516"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"ID": "CVE-2020-8219",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Pulse Connect Secure",
"version": {
"version_data": [
{
"version_value": "Fixed in 9.1R8"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An insufficient permission check vulnerability exists in Pulse Connect Secure \u003c9.1R8 that allows an attacker to change the password of a full administrator."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Handling of Insufficient Permissions or Privileges (CWE-280)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44516",
"refsource": "MISC",
"url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44516"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2020-8219",
"datePublished": "2020-07-30T12:53:02.000Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:56:27.612Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-8117 (GCVE-0-2020-8117)
Vulnerability from cvelistv5 – Published: 2020-02-04 19:08 – Updated: 2024-08-04 09:48- CWE-280 - Improper Handling of Insufficient Permissions or Privileges (CWE-280)
| URL | Tags |
|---|---|
| https://hackerone.com/reports/439828 | x_refsource_MISC |
| https://nextcloud.com/security/advisory/?id=NC-SA… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Nextcloud Server |
Affected:
14.0.4
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:48:25.578Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/439828"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://nextcloud.com/security/advisory/?id=NC-SA-2020-013"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Nextcloud Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "14.0.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper preservation of permissions in Nextcloud Server 14.0.3 causes the event details to be leaked when sharing a non-public event."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "Improper Handling of Insufficient Permissions or Privileges (CWE-280)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-04T19:08:57.000Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/439828"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://nextcloud.com/security/advisory/?id=NC-SA-2020-013"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"ID": "CVE-2020-8117",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Nextcloud Server",
"version": {
"version_data": [
{
"version_value": "14.0.4"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper preservation of permissions in Nextcloud Server 14.0.3 causes the event details to be leaked when sharing a non-public event."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Handling of Insufficient Permissions or Privileges (CWE-280)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://hackerone.com/reports/439828",
"refsource": "MISC",
"url": "https://hackerone.com/reports/439828"
},
{
"name": "https://nextcloud.com/security/advisory/?id=NC-SA-2020-013",
"refsource": "MISC",
"url": "https://nextcloud.com/security/advisory/?id=NC-SA-2020-013"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2020-8117",
"datePublished": "2020-02-04T19:08:57.000Z",
"dateReserved": "2020-01-28T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:48:25.578Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-3427 (GCVE-0-2020-3427)
Vulnerability from cvelistv5 – Published: 2020-10-14 18:15 – Updated: 2024-11-13 17:51- CWE-280 - Improper Handling of Insufficient Permissions or Privileges
| URL | Tags |
|---|---|
| https://duo.com/docs/rdp-notes | vendor-advisoryx_refsource_CISCO |
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Duo Authentication for Windows Logon and RDP |
Affected:
unspecified , < 4.1.2
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T07:30:58.168Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "Duo Authentication for Windows Logon and RDP Privilege Escalation Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://duo.com/docs/rdp-notes"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-3427",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-13T17:17:31.700724Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-13T17:51:09.154Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Duo Authentication for Windows Logon and RDP",
"vendor": "Cisco",
"versions": [
{
"lessThan": "4.1.2",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was reported by Ido Hoorvitch from CyberArk"
}
],
"datePublic": "2020-10-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Windows Logon installer prior to 4.1.2 did not properly validate file installation paths. This allows an attacker with local user privileges to coerce the installer to write to arbitrary privileged directories. If successful, an attacker can manipulate files used by Windows Logon, cause Denial of Service (DoS) by deleting file(s), or replace system files to potentially achieve elevation of privileges. Note that this can only exploitable during new installations while the installer is running and is not exploitable once installation is finished. Versions 4.1.2 of Windows Logon addresses this issue."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "CWE-280 Improper Handling of Insufficient Permissions or Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-19T16:17:40.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "Duo Authentication for Windows Logon and RDP Privilege Escalation Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://duo.com/docs/rdp-notes"
}
],
"source": {
"advisory": "Version-4.1.2-release-notes",
"discovery": "EXTERNAL"
},
"title": "Duo Authentication for Windows Logon and RDP Privilege Escalation Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2020-10-14T16:00:00.000Z",
"ID": "CVE-2020-3427",
"STATE": "PUBLIC",
"TITLE": "Duo Authentication for Windows Logon and RDP Privilege Escalation Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Duo Authentication for Windows Logon and RDP",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.1.2"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This issue was reported by Ido Hoorvitch from CyberArk"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Windows Logon installer prior to 4.1.2 did not properly validate file installation paths. This allows an attacker with local user privileges to coerce the installer to write to arbitrary privileged directories. If successful, an attacker can manipulate files used by Windows Logon, cause Denial of Service (DoS) by deleting file(s), or replace system files to potentially achieve elevation of privileges. Note that this can only exploitable during new installations while the installer is running and is not exploitable once installation is finished. Versions 4.1.2 of Windows Logon addresses this issue."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-280 Improper Handling of Insufficient Permissions or Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "Duo Authentication for Windows Logon and RDP Privilege Escalation Vulnerability",
"refsource": "CISCO",
"url": "https://duo.com/docs/rdp-notes"
}
]
},
"source": {
"advisory": "Version-4.1.2-release-notes",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2020-3427",
"datePublished": "2020-10-14T18:15:25.991Z",
"dateReserved": "2019-12-12T00:00:00.000Z",
"dateUpdated": "2024-11-13T17:51:09.154Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-17437 (GCVE-0-2019-17437)
Vulnerability from cvelistv5 – Published: 2019-12-05 14:11 – Updated: 2024-09-17 04:10- CWE-280 - Improper Handling of Insufficient Permissions or Privileges
| URL | Tags |
|---|---|
| https://securityadvisories.paloaltonetworks.com/H… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Palo Alto Networks | PAN-OS |
Unknown:
unspecified , ≤ 7.0
(custom)
Affected: 7.1 , < 7.1.25 (custom) Affected: 8.0 , < 8.0.20 (custom) Affected: 8.1 , < 8.1.11 (custom) Affected: 9.0 , < 9.0.5 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:40:15.857Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://securityadvisories.paloaltonetworks.com/Home/Detail/159"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PAN-OS",
"vendor": "Palo Alto Networks",
"versions": [
{
"lessThanOrEqual": "7.0",
"status": "unknown",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "7.1.25",
"status": "affected",
"version": "7.1",
"versionType": "custom"
},
{
"lessThan": "8.0.20",
"status": "affected",
"version": "8.0",
"versionType": "custom"
},
{
"lessThan": "8.1.11",
"status": "affected",
"version": "8.1",
"versionType": "custom"
},
{
"lessThan": "9.0.5",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"value": "This issue only affects devices configured with a low privileged custom-role user."
}
],
"credits": [
{
"lang": "en",
"value": "Christophe Schleypen of NCIA / NCIRC"
}
],
"datePublic": "2019-12-04T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An improper authentication check in Palo Alto Networks PAN-OS may allow an authenticated low privileged non-superuser custom role user to elevate privileges and become superuser. This issue affects PAN-OS 7.1 versions prior to 7.1.25; 8.0 versions prior to 8.0.20; 8.1 versions prior to 8.1.11; 9.0 versions prior to 9.0.5. PAN-OS version 7.0 and prior EOL versions have not been evaluated for this issue."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "CWE-280 Improper Handling of Insufficient Permissions or Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-12-05T14:11:11.000Z",
"orgId": "d6c1279f-00f6-4ef7-9217-f89ffe703ec0",
"shortName": "palo_alto"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://securityadvisories.paloaltonetworks.com/Home/Detail/159"
}
],
"solutions": [
{
"lang": "en",
"value": "This issue has been resolved in 7.1.25, 8.0.20, 8.1.11, 9.0.5 and all subsequent versions."
}
],
"source": {
"advisory": "PAN-SA-2019-0038",
"defect": [
"PAN-115697"
],
"discovery": "EXTERNAL"
},
"title": "PAN-OS: Custom-role users may escalate privileges",
"workarounds": [
{
"lang": "en",
"value": "Remove any untrusted custom-role users from the device or disable their access until fixes can be applied. Restrict access to the device to only trusted users."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@paloaltonetworks.com",
"DATE_PUBLIC": "2019-12-04T17:00:00.000Z",
"ID": "CVE-2019-17437",
"STATE": "PUBLIC",
"TITLE": "PAN-OS: Custom-role users may escalate privileges"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PAN-OS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "7.1",
"version_value": "7.1.25"
},
{
"version_affected": "\u003c",
"version_name": "8.0",
"version_value": "8.0.20"
},
{
"version_affected": "\u003c",
"version_name": "8.1",
"version_value": "8.1.11"
},
{
"version_affected": "\u003c",
"version_name": "9.0",
"version_value": "9.0.5"
},
{
"version_affected": "?\u003c=",
"version_value": "7.0"
}
]
}
}
]
},
"vendor_name": "Palo Alto Networks"
}
]
}
},
"configuration": [
{
"lang": "en",
"value": "This issue only affects devices configured with a low privileged custom-role user."
}
],
"credit": [
{
"lang": "eng",
"value": "Christophe Schleypen of NCIA / NCIRC"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An improper authentication check in Palo Alto Networks PAN-OS may allow an authenticated low privileged non-superuser custom role user to elevate privileges and become superuser. This issue affects PAN-OS 7.1 versions prior to 7.1.25; 8.0 versions prior to 8.0.20; 8.1 versions prior to 8.1.11; 9.0 versions prior to 9.0.5. PAN-OS version 7.0 and prior EOL versions have not been evaluated for this issue."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-280 Improper Handling of Insufficient Permissions or Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://securityadvisories.paloaltonetworks.com/Home/Detail/159",
"refsource": "CONFIRM",
"url": "https://securityadvisories.paloaltonetworks.com/Home/Detail/159"
}
]
},
"solution": [
{
"lang": "en",
"value": "This issue has been resolved in 7.1.25, 8.0.20, 8.1.11, 9.0.5 and all subsequent versions."
}
],
"source": {
"advisory": "PAN-SA-2019-0038",
"defect": [
"PAN-115697"
],
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Remove any untrusted custom-role users from the device or disable their access until fixes can be applied. Restrict access to the device to only trusted users."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "d6c1279f-00f6-4ef7-9217-f89ffe703ec0",
"assignerShortName": "palo_alto",
"cveId": "CVE-2019-17437",
"datePublished": "2019-12-05T14:11:11.290Z",
"dateReserved": "2019-10-10T00:00:00.000Z",
"dateUpdated": "2024-09-17T04:10:31.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13415 (GCVE-0-2019-13415)
Vulnerability from cvelistv5 – Published: 2019-08-13 18:59 – Updated: 2024-08-04 23:49- CWE-280 - Improper Handling of Insufficient Permissions or Privileges
| URL | Tags |
|---|---|
| https://search-guard.com/cve-advisory/ | x_refsource_MISC |
| https://docs.search-guard.com/6.x-25/changelog-se… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| floragunn | Search Guard |
Affected:
before 24.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:49:25.025Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://search-guard.com/cve-advisory/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://docs.search-guard.com/6.x-25/changelog-searchguard-6-x-24_3"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Search Guard",
"vendor": "floragunn",
"versions": [
{
"status": "affected",
"version": "before 24.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Search Guard versions before 24.3 had an issue when Cross Cluster Search (CCS) was enabled, authenticated users can gain read access to data they are not authorized to see."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "CWE-280: Improper Handling of Insufficient Permissions or Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-13T18:59:59.000Z",
"orgId": "9f311a02-c44f-4938-8530-9219246b8255",
"shortName": "floragunn"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://search-guard.com/cve-advisory/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://docs.search-guard.com/6.x-25/changelog-searchguard-6-x-24_3"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@search-guard.com",
"ID": "CVE-2019-13415",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Search Guard",
"version": {
"version_data": [
{
"version_value": "before 24.3"
}
]
}
}
]
},
"vendor_name": "floragunn"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Search Guard versions before 24.3 had an issue when Cross Cluster Search (CCS) was enabled, authenticated users can gain read access to data they are not authorized to see."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-280: Improper Handling of Insufficient Permissions or Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://search-guard.com/cve-advisory/",
"refsource": "MISC",
"url": "https://search-guard.com/cve-advisory/"
},
{
"name": "https://docs.search-guard.com/6.x-25/changelog-searchguard-6-x-24_3",
"refsource": "CONFIRM",
"url": "https://docs.search-guard.com/6.x-25/changelog-searchguard-6-x-24_3"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9f311a02-c44f-4938-8530-9219246b8255",
"assignerShortName": "floragunn",
"cveId": "CVE-2019-13415",
"datePublished": "2019-08-13T18:59:59.000Z",
"dateReserved": "2019-07-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:49:25.025Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation MIT-46
Strategy: Separation of Privilege
- Compartmentalize the system to have "safe" areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
- Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
Mitigation
Always check to see if you have successfully accessed a resource or system functionality, and use proper error handling if it is unsuccessful. Do this even when you are operating in a highly privileged mode, because errors or environmental conditions might still cause a failure. For example, environments with highly granular permissions/privilege models, such as Windows or Linux capabilities, can cause unexpected failures.
No CAPEC attack patterns related to this CWE.