Common Weakness Enumeration
CWE-256
AllowedPlaintext Storage of a Password
Abstraction: Base · Status: Incomplete
The product stores a password in plaintext within resources such as memory or files.
427 vulnerabilities reference this CWE, most recent first.
CVE-2024-53292 (GCVE-0-2024-53292)
Vulnerability from cvelistv5 – Published: 2024-12-11 07:55 – Updated: 2024-12-11 15:09
VLAI
EPSS
VEX
Summary
Dell VxVerify, versions prior to x.40.405, contain a Plain-text Password Storage Vulnerability in the shell wrapper. A local high privileged attacker could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable component with privileges of the compromised account.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-11 15:09 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00025896… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell VxRail HCI |
Affected:
N/A , < x.40.405
(semver)
|
Date Public
2024-12-10 18:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-53292",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-11T15:09:16.727089Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-11T15:09:35.982Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell VxRail HCI",
"vendor": "Dell",
"versions": [
{
"lessThan": "x.40.405",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-12-10T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell VxVerify, versions prior to x.40.405, contain a Plain-text Password Storage Vulnerability in the shell wrapper. A local high privileged attacker could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable component with privileges of the compromised account."
}
],
"value": "Dell VxVerify, versions prior to x.40.405, contain a Plain-text Password Storage Vulnerability in the shell wrapper. A local high privileged attacker could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable component with privileges of the compromised account."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256: Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-11T07:55:24.383Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000258964/dsa-2024-492-security-update-dell-vxverify-on-vxrail-plaintext-password-storage-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-53292",
"datePublished": "2024-12-11T07:55:24.383Z",
"dateReserved": "2024-11-20T06:05:04.566Z",
"dateUpdated": "2024-12-11T15:09:35.982Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-52361 (GCVE-0-2024-52361)
Vulnerability from cvelistv5 – Published: 2024-12-18 15:26 – Updated: 2024-12-18 15:58
VLAI
EPSS
VEX
Title
IBM Storage Defender - Resiliency Service information disclosure
Summary
IBM Storage Defender - Resiliency Service 2.0.0 through 2.0.9
stores user credentials in plain text which can be read by an authenticated user with access to the pod.
Severity
5.7 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-18 15:58 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7178587 | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Storage Defender - Resiliency Service |
Affected:
2.0.0 , ≤ 2.0.9
(semver)
cpe:2.3:a:ibm:storage_defender_resiliency_service:2.0.0:*:*:*:*:*:*:* cpe:2.3:a:ibm:storage_defender_resiliency_service:2.0.9:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-52361",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-18T15:58:25.641492Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-18T15:58:37.023Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:storage_defender_resiliency_service:2.0.0:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:storage_defender_resiliency_service:2.0.9:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "Storage Defender - Resiliency Service",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "2.0.9",
"status": "affected",
"version": "2.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIBM Storage Defender - Resiliency Service 2.0.0 through 2.0.9 \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;stores user credentials in plain text which can be read by an authenticated user with access to the pod.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
}
],
"value": "IBM Storage Defender - Resiliency Service 2.0.0 through 2.0.9 \n\n\n\n\u00a0stores user credentials in plain text which can be read by an authenticated user with access to the pod."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-18T15:26:43.535Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ibm.com/support/pages/node/7178587"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM Storage Defender - Resiliency Service information disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2024-52361",
"datePublished": "2024-12-18T15:26:43.535Z",
"dateReserved": "2024-11-10T16:11:09.566Z",
"dateUpdated": "2024-12-18T15:58:37.023Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-49370 (GCVE-0-2024-49370)
Vulnerability from cvelistv5 – Published: 2024-10-23 15:10 – Updated: 2024-10-23 17:29
VLAI
EPSS
VEX
Title
Change-Password via Portal-Profile sets PimcoreBackendUser password without hashing
Summary
Pimcore is an open source data and experience management platform. When a PortalUserObject is connected to a PimcoreUser and "Use Pimcore Backend Password" is set to true, the change password function in Portal Profile sets the new password. Prior to Pimcore portal engine versions 4.1.7 and 3.1.16, the password is then set without hashing so it can be read by everyone. Everyone who combines PortalUser to PimcoreUsers and change passwords via profile settings could be affected. Versions 4.1.7 and 3.1.16 of the Pimcore portal engine fix the issue.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-23 17:24 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://github.com/pimcore/pimcore/security/advis… | x_refsource_CONFIRM |
Impacted products
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:pimcore:pimcore:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "pimcore",
"vendor": "pimcore",
"versions": [
{
"lessThan": "3.1.16",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.1.7",
"status": "affected",
"version": "4.0.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-49370",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T17:24:31.062435Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T17:29:27.020Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "pimcore",
"vendor": "pimcore",
"versions": [
{
"status": "affected",
"version": "\u003c 3.1.16"
},
{
"status": "affected",
"version": "\u003e= 4.0.0, \u003c 4.1.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Pimcore is an open source data and experience management platform. When a PortalUserObject is connected to a PimcoreUser and \"Use Pimcore Backend Password\" is set to true, the change password function in Portal Profile sets the new password. Prior to Pimcore portal engine versions 4.1.7 and 3.1.16, the password is then set without hashing so it can be read by everyone. Everyone who combines PortalUser to PimcoreUsers and change passwords via profile settings could be affected. Versions 4.1.7 and 3.1.16 of the Pimcore portal engine fix the issue."
}
],
"metrics": [
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256: Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T15:10:34.393Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/pimcore/pimcore/security/advisories/GHSA-74p5-77rq-gfqc",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/pimcore/pimcore/security/advisories/GHSA-74p5-77rq-gfqc"
}
],
"source": {
"advisory": "GHSA-74p5-77rq-gfqc",
"discovery": "UNKNOWN"
},
"title": "Change-Password via Portal-Profile sets PimcoreBackendUser password without hashing"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2024-49370",
"datePublished": "2024-10-23T15:10:34.393Z",
"dateReserved": "2024-10-14T13:56:34.811Z",
"dateUpdated": "2024-10-23T17:29:27.020Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-49351 (GCVE-0-2024-49351)
Vulnerability from cvelistv5 – Published: 2024-11-26 03:11 – Updated: 2024-11-26 15:42
VLAI
EPSS
VEX
Title
IBM Workload Scheduler information disclosure
Summary
IBM Workload Scheduler 9.5, 10.1, and 10.2 stores user credentials in plain text which can be read by a local user.
Severity
5.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-26 15:42 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Workload Scheduler |
Affected:
9.5, 10.1, 10.2
cpe:2.3:a:ibm:tivoli_workload_scheduler:9.5:*:*:*:*:*:*:* cpe:2.3:a:ibm:tivoli_workload_scheduler:10.1:*:*:*:*:*:*:* cpe:2.3:a:ibm:tivoli_workload_scheduler:10.2:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-49351",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-26T15:42:09.115956Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T15:42:29.302Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:tivoli_workload_scheduler:9.5:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:tivoli_workload_scheduler:10.1:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:tivoli_workload_scheduler:10.2:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "Workload Scheduler",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "9.5, 10.1, 10.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM Workload Scheduler 9.5, 10.1, and 10.2 stores user credentials in plain text which can be read by a local user."
}
],
"value": "IBM Workload Scheduler 9.5, 10.1, and 10.2 stores user credentials in plain text which can be read by a local user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-26T03:11:52.593Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"url": "https://www.ibm.com/support/pages/node/7177061"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM Workload Scheduler information disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2024-49351",
"datePublished": "2024-11-26T03:11:52.593Z",
"dateReserved": "2024-10-14T12:05:24.914Z",
"dateUpdated": "2024-11-26T15:42:29.302Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45638 (GCVE-0-2024-45638)
Vulnerability from cvelistv5 – Published: 2025-03-14 14:49 – Updated: 2025-09-01 01:05
VLAI
EPSS
VEX
Title
IBM QRadar EDR information disclosure
Summary
IBM Security QRadar 3.12 EDR stores user credentials in plain text which can be read by a local privileged user.
Severity
4.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-14 18:41 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7185938 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | QRadar EDR |
Affected:
3.12
cpe:2.3:a:ibm:security_qradar_edr:3.12:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45638",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-14T18:41:27.680123Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-14T18:50:23.821Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:security_qradar_edr:3.12:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "QRadar EDR",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "3.12"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM Security QRadar 3.12 EDR stores user credentials in plain text which can be read by a local privileged user."
}
],
"value": "IBM Security QRadar 3.12 EDR stores user credentials in plain text which can be read by a local privileged user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-01T01:05:22.574Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7185938"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM QRadar EDR information disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2024-45638",
"datePublished": "2025-03-14T14:49:52.646Z",
"dateReserved": "2024-09-03T13:50:17.059Z",
"dateUpdated": "2025-09-01T01:05:22.574Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45636 (GCVE-0-2024-45636)
Vulnerability from cvelistv5 – Published: 2026-06-11 15:10 – Updated: 2026-06-11 15:41
VLAI
EPSS
VEX
Title
IBM Security QRadar EDR Software has a vulnerability where user credentials may be stored in plain text, potentially exposing sensitive information.
Summary
IBM Security QRadar EDR 3.12 through 3.12.24 stores user credentials in plain text which can be read by a local privileged user.
Severity
4.1 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-11 15:41 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7274828 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Security QRadar EDR |
Affected:
3.12.0 , ≤ 3.12.24
(semver)
cpe:2.3:a:ibm:security_qradar_edr:3.12:*:*:*:*:*:*:* cpe:2.3:a:ibm:security_qradar_edr:3.12.0:*:*:*:*:*:*:* cpe:2.3:a:ibm:security_qradar_edr:3.12.24:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45636",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-11T15:41:43.602422Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-11T15:41:51.536Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:security_qradar_edr:3.12:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:security_qradar_edr:3.12.0:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:security_qradar_edr:3.12.24:*:*:*:*:*:*:*"
],
"product": "Security QRadar EDR",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "3.12.24",
"status": "affected",
"version": "3.12.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Security QRadar EDR 3.12 through 3.12.24 stores user credentials in plain text which can be read by a local privileged user.\u003c/p\u003e"
}
],
"value": "IBM Security QRadar EDR 3.12 through 3.12.24 stores user credentials in plain text which can be read by a local privileged user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-11T15:10:38.269Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7274828"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM encourages customers to update their systems promptly.\u003c/p\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003eProduct\u003c/td\u003e\u003ctd\u003eFix version\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003eIBM Security QRadar EDR\u003c/td\u003e\u003ctd\u003e3.12.25\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003c/div\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003eThe IBM Security QRadar EDR operator can be upgraded automatically when new compatible versions are available. However, you can control whether an operator is upgraded automatically by setting an approval strategy.\u003c/p\u003e\u003cdiv\u003e\u003cp\u003eTwo approval strategies are available:\u003c/p\u003e\u003cul\u003e\u003cli\u003eAutomatic (default) - New operator versions are installed automatically when they are available on the subscription channel.\u003c/li\u003e\u003cli\u003eManual - When a new operator version is available on the subscription channel, the subscription indicates that an update is available, but you must approve the update manually.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information about the manual installation process, view\u0026nbsp;\u003ca href=\"https://www.ibm.com/docs/en/security-qradar-edr/3.12?topic=overview-whats-new-changed\" rel=\"noopener noreferrer nofollow\"\u003eInstalling QRadar EDR\u003c/a\u003e\u003c/p\u003e\u003c/div\u003e"
}
],
"value": "IBM encourages customers to update their systems promptly.\n\nProductFix versionIBM Security QRadar EDR3.12.25\n\n\n\n\n\n\n\nThe IBM Security QRadar EDR operator can be upgraded automatically when new compatible versions are available. However, you can control whether an operator is upgraded automatically by setting an approval strategy.\n\n\n\nTwo approval strategies are available:\n\n * Automatic (default) - New operator versions are installed automatically when they are available on the subscription channel.\n * Manual - When a new operator version is available on the subscription channel, the subscription indicates that an update is available, but you must approve the update manually.\n\n\n\n\nFor more information about the manual installation process, view\u00a0 Installing QRadar EDR https://www.ibm.com/docs/en/security-qradar-edr/3.12"
}
],
"title": "IBM Security QRadar EDR Software has a vulnerability where user credentials may be stored in plain text, potentially exposing sensitive information.",
"x_generator": {
"engine": "ibm-cvegen"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2024-45636",
"datePublished": "2026-06-11T15:10:38.269Z",
"dateReserved": "2024-09-03T13:49:55.577Z",
"dateUpdated": "2026-06-11T15:41:51.536Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-45283 (GCVE-0-2024-45283)
Vulnerability from cvelistv5 – Published: 2024-09-10 04:52 – Updated: 2024-09-10 13:46
VLAI
EPSS
VEX
Title
Information disclosure vulnerability in SAP NetWeaver AS for Java (Destination Service)
Summary
SAP NetWeaver AS for Java allows an authorized attacker to obtain sensitive information. The attacker could obtain the username and password when creating an RFC destination. After successful exploitation, an attacker can read the sensitive information but cannot modify or delete the data.
Severity
6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-10 13:46 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
2 references
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| SAP_SE | SAP NetWeaver AS for Java (Destination Service) |
Affected:
7.50
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45283",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T13:46:01.984548Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T13:46:19.680Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SAP NetWeaver AS for Java (Destination Service)",
"vendor": "SAP_SE",
"versions": [
{
"status": "affected",
"version": "7.50"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSAP NetWeaver AS for Java allows an authorized attacker to obtain sensitive information. The attacker could obtain the username and password when creating an RFC destination. After successful exploitation, an attacker can read the sensitive information but cannot modify or delete the data.\u003c/p\u003e"
}
],
"value": "SAP NetWeaver AS for Java allows an authorized attacker to obtain sensitive information. The attacker could obtain the username and password when creating an RFC destination. After successful exploitation, an attacker can read the sensitive information but cannot modify or delete the data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256: Plaintext Storage of a Password",
"lang": "eng",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T04:52:30.209Z",
"orgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"shortName": "sap"
},
"references": [
{
"url": "https://me.sap.com/notes/3477359"
},
{
"url": "https://url.sap/sapsecuritypatchday"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Information disclosure vulnerability in SAP NetWeaver AS for Java (Destination Service)",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"assignerShortName": "sap",
"cveId": "CVE-2024-45283",
"datePublished": "2024-09-10T04:52:30.209Z",
"dateReserved": "2024-08-26T10:39:20.933Z",
"dateUpdated": "2024-09-10T13:46:19.680Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43659 (GCVE-0-2024-43659)
Vulnerability from cvelistv5 – Published: 2025-01-09 07:56 – Updated: 2025-03-11 13:07
VLAI
EPSS
VEX
Title
Plaintext default credentials in firmware
Summary
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.
This issue affects Iocharger firmware for AC models before firmware version 25010801.
The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.
Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.
Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-09 14:48 UTC
CWE
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory |
| https://csirt.divd.nl/CVE-2024-43659/ | third-party-advisory |
| https://iocharger.com | product |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Iocharger | Iocharger firmware for AC models |
Affected:
0 , < 25010801
(custom)
|
Date Public
2025-01-09 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-43659",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T14:48:10.199874Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T14:48:39.535Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "25010801",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After gaining access to the firmware of a charging station, a file at \u0026lt;redacted\u0026gt; can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.\u003cbr\u003e\u003cbr\u003eThis issue affects Iocharger firmware for AC models before firmware version 25010801. \u003cbr\u003e\u003cbr\u003eThe issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using \u0026lt;redacted\u0026gt;.sh) to gain access to the \u0026lt;redacted\u0026gt;.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System \u2192 Custom page.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the \"super user\" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e"
}
],
"value": "After gaining access to the firmware of a charging station, a file at \u003credacted\u003e can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.\n\nThis issue affects Iocharger firmware for AC models before firmware version 25010801. \n\nThe issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.\n\nLikelihood: Moderate \u2013 The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using \u003credacted\u003e.sh) to gain access to the \u003credacted\u003e.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.\n\nImpact: Critical \u2013 All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System \u2192 Custom page.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the \"super user\" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-653",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-653: Use of Known Operating System Credentials"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/S:P/AU:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1391",
"description": "CWE-1391 Use of Weak Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-1393",
"description": "CWE-1393 Use of Default Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:10.334Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43659/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Plaintext default credentials in firmware",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43659",
"datePublished": "2025-01-09T07:56:45.847Z",
"dateReserved": "2024-08-14T09:27:41.769Z",
"dateUpdated": "2025-03-11T13:07:10.334Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43378 (GCVE-0-2024-43378)
Vulnerability from cvelistv5 – Published: 2024-08-15 23:53 – Updated: 2024-09-03 18:02
VLAI
EPSS
VEX
Title
calamares-nixos-extensions LUKS keyfile exposure regression on legacy BIOS systems
Summary
calamares-nixos-extensions provides Calamares branding and modules for NixOS, a distribution of GNU/Linux. Users who installed NixOS through the graphical installer who used manual disk partitioning to create a setup where the system was booted via legacy BIOS rather than UEFI; some disk partitions are encrypted; but the partitions containing either `/` or `/boot` are unencrypted; have their LUKS disk encryption key file in plain text either in `/crypto_keyfile.bin`, or in a CPIO archive attached to their NixOS initrd. `nixos-install` is not affected, nor are UEFI installations, nor was the default automatic partitioning configuration on legacy BIOS systems. The problem has been fixed in calamares-nixos-extensions 0.3.17, which was included in NixOS. The current installer images for the NixOS 24.05 and unstable (24.11) channels are unaffected. The fix reached 24.05 at 2024-08-13 20:06:59 UTC, and unstable at 2024-08-15 09:00:20 UTC. Installer images downloaded before those times may be vulnerable. The best solution for affected users is probably to back up their data and do a complete reinstallation. However, the mitigation procedure in GHSA-3rvf-24q2-24ww should work solely for the case where `/` is encrypted but `/boot` is not. If `/` is unencrypted, then the `/crypto_keyfile.bin` file will need to be deleted in addition to the remediation steps in the previous advisory. This issue is a partial regression of CVE-2023-36476 / GHSA-3rvf-24q2-24ww, which was more severe as it applied to the default configuration on BIOS systems.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-19 20:54 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://github.com/NixOS/calamares-nixos-extensio… | x_refsource_CONFIRM |
| https://github.com/NixOS/calamares-nixos-extensio… | x_refsource_MISC |
| https://github.com/NixOS/calamares-nixos-extensio… | x_refsource_MISC |
| https://github.com/NixOS/nixpkgs/pull/331607 | x_refsource_MISC |
| https://github.com/NixOS/nixpkgs/pull/334252 | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| NixOS | calamares-nixos-extensions |
Affected:
< 0.3.17
|
|
| nixos | calamares-nixos-extensions |
Affected:
0 , < 0.3.17
(custom)
cpe:2.3:a:nixos:calamares-nixos-extensions:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:nixos:calamares-nixos-extensions:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "calamares-nixos-extensions",
"vendor": "nixos",
"versions": [
{
"lessThan": "0.3.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-43378",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-19T20:54:33.909326Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-03T18:02:47.756Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "calamares-nixos-extensions",
"vendor": "NixOS",
"versions": [
{
"status": "affected",
"version": "\u003c 0.3.17"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "calamares-nixos-extensions provides Calamares branding and modules for NixOS, a distribution of GNU/Linux. Users who installed NixOS through the graphical installer who used manual disk partitioning to create a setup where the system was booted via legacy BIOS rather than UEFI; some disk partitions are encrypted; but the partitions containing either `/` or `/boot` are unencrypted; have their LUKS disk encryption key file in plain text either in `/crypto_keyfile.bin`, or in a CPIO archive attached to their NixOS initrd. `nixos-install` is not affected, nor are UEFI installations, nor was the default automatic partitioning configuration on legacy BIOS systems. The problem has been fixed in calamares-nixos-extensions 0.3.17, which was included in NixOS. The current installer images for the NixOS 24.05 and unstable (24.11) channels are unaffected. The fix reached 24.05 at 2024-08-13 20:06:59 UTC, and unstable at 2024-08-15 09:00:20 UTC. Installer images downloaded before those times may be vulnerable. The best solution for affected users is probably to back up their data and do a complete reinstallation. However, the mitigation procedure in GHSA-3rvf-24q2-24ww should work solely for the case where `/` is encrypted but `/boot` is not. If `/` is unencrypted, then the `/crypto_keyfile.bin` file will need to be deleted in addition to the remediation steps in the previous advisory. This issue is a partial regression of CVE-2023-36476 / GHSA-3rvf-24q2-24ww, which was more severe as it applied to the default configuration on BIOS systems."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256: Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-15T23:53:07.103Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"name": "https://github.com/NixOS/calamares-nixos-extensions/security/advisories/GHSA-vfxf-gpmj-2p25",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/NixOS/calamares-nixos-extensions/security/advisories/GHSA-vfxf-gpmj-2p25"
},
{
"name": "https://github.com/NixOS/calamares-nixos-extensions/security/advisories/GHSA-3rvf-24q2-24ww",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/NixOS/calamares-nixos-extensions/security/advisories/GHSA-3rvf-24q2-24ww"
},
{
"name": "https://github.com/NixOS/calamares-nixos-extensions/pull/43",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/NixOS/calamares-nixos-extensions/pull/43"
},
{
"name": "https://github.com/NixOS/nixpkgs/pull/331607",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/NixOS/nixpkgs/pull/331607"
},
{
"name": "https://github.com/NixOS/nixpkgs/pull/334252",
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/NixOS/nixpkgs/pull/334252"
}
],
"source": {
"advisory": "GHSA-vfxf-gpmj-2p25",
"discovery": "UNKNOWN"
},
"title": "calamares-nixos-extensions LUKS keyfile exposure regression on legacy BIOS systems"
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2024-43378",
"datePublished": "2024-08-15T23:53:07.103Z",
"dateReserved": "2024-08-09T14:23:55.514Z",
"dateUpdated": "2024-09-03T18:02:47.756Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-43186 (GCVE-0-2024-43186)
Vulnerability from cvelistv5 – Published: 2025-03-28 23:49 – Updated: 2025-09-01 01:00
VLAI
EPSS
VEX
Title
IBM InfoSphere Information Server information disclosure
Summary
IBM InfoSphere Information Server 11.7 could allow an authenticated user to obtain sensitive information that is stored locally under certain conditions.
Severity
5.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-31 14:23 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7184980 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | InfoSphere Information Server |
Affected:
11.7
cpe:2.3:a:ibm:infosphere_information_server:11.7:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-43186",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-31T14:23:03.458890Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-01T14:39:27.284Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:infosphere_information_server:11.7:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "InfoSphere Information Server",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "11.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM InfoSphere Information Server 11.7 could allow an authenticated user to obtain sensitive information that is stored locally under certain conditions."
}
],
"value": "IBM InfoSphere Information Server 11.7 could allow an authenticated user to obtain sensitive information that is stored locally under certain conditions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-01T01:00:28.126Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7184980"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM InfoSphere Information Server information disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2024-43186",
"datePublished": "2025-03-28T23:49:20.873Z",
"dateReserved": "2024-08-07T13:29:34.028Z",
"dateUpdated": "2025-09-01T01:00:28.126Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Architecture and Design
Avoid storing passwords in easily accessible locations.
Mitigation
Architecture and Design
Consider storing cryptographic hashes of passwords as an alternative to storing in plaintext.
Mitigation
A programmer might attempt to remedy the password management problem by obscuring the password with an encoding function, such as base 64 encoding, but this effort does not adequately protect the password because the encoding can be detected and decoded easily.
No CAPEC attack patterns related to this CWE.