Common Weakness Enumeration

CWE-248

Allowed

Uncaught Exception

Abstraction: Base · Status: Draft

An exception is thrown from a function, but it is not caught.

610 vulnerabilities reference this CWE, most recent first.

CVE-2020-27121 (GCVE-0-2020-27121)

Vulnerability from cvelistv5 – Published: 2020-11-06 18:15 – Updated: 2024-11-13 17:44
VLAI
Title
Cisco Unified Communications Manager IM and Presence Service Denial of Service Vulnerability
Summary
A vulnerability in Cisco Unified Communications Manager IM & Presence Service (Unified CM IM&P) Software could allow an authenticated, remote attacker to cause the Cisco XCP Authentication Service on an affected device to restart, resulting in a denial of service (DoS) condition. The vulnerability is due to improper handling of login requests. An attacker could exploit this vulnerability by sending a crafted client login request to an affected device. A successful exploit could allow the attacker to cause a process to crash, resulting in a DoS condition for new login attempts. Users who are authenticated at the time of the attack would not be affected. There are workarounds that address this vulnerability.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-13 17:22 UTC
CWE
References
URL Tags
https://tools.cisco.com/security/center/content/C… vendor-advisoryx_refsource_CISCO
Date Public
2020-11-04 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:11:35.479Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20201104 Cisco Unified Communications Manager IM and Presence Service Denial of Service Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-imp-dos-uTx2dqu2"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-27121",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-13T17:22:36.184575Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-13T17:44:46.213Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Unified Communications Manager IM and Presence Service",
          "vendor": "Cisco",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-11-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in Cisco Unified Communications Manager IM \u0026amp; Presence Service (Unified CM IM\u0026amp;P) Software could allow an authenticated, remote attacker to cause the Cisco XCP Authentication Service on an affected device to restart, resulting in a denial of service (DoS) condition. The vulnerability is due to improper handling of login requests. An attacker could exploit this vulnerability by sending a crafted client login request to an affected device. A successful exploit could allow the attacker to cause a process to crash, resulting in a DoS condition for new login attempts. Users who are authenticated at the time of the attack would not be affected. There are workarounds that address this vulnerability."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-06T18:15:38.000Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20201104 Cisco Unified Communications Manager IM and Presence Service Denial of Service Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-imp-dos-uTx2dqu2"
        }
      ],
      "source": {
        "advisory": "cisco-sa-imp-dos-uTx2dqu2",
        "defect": [
          [
            "CSCvv75814"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Unified Communications Manager IM and Presence Service Denial of Service Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2020-11-04T16:00:00",
          "ID": "CVE-2020-27121",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Unified Communications Manager IM and Presence Service Denial of Service Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Unified Communications Manager IM and Presence Service",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in Cisco Unified Communications Manager IM \u0026amp; Presence Service (Unified CM IM\u0026amp;P) Software could allow an authenticated, remote attacker to cause the Cisco XCP Authentication Service on an affected device to restart, resulting in a denial of service (DoS) condition. The vulnerability is due to improper handling of login requests. An attacker could exploit this vulnerability by sending a crafted client login request to an affected device. A successful exploit could allow the attacker to cause a process to crash, resulting in a DoS condition for new login attempts. Users who are authenticated at the time of the attack would not be affected. There are workarounds that address this vulnerability."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "4.3",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20201104 Cisco Unified Communications Manager IM and Presence Service Denial of Service Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-imp-dos-uTx2dqu2"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-imp-dos-uTx2dqu2",
          "defect": [
            [
              "CSCvv75814"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2020-27121",
    "datePublished": "2020-11-06T18:15:38.587Z",
    "dateReserved": "2020-10-13T00:00:00.000Z",
    "dateUpdated": "2024-11-13T17:44:46.213Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-15796 (GCVE-0-2020-15796)

Vulnerability from cvelistv5 – Published: 2020-12-14 21:05 – Updated: 2024-08-04 13:30
VLAI
Summary
A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) (V20.8), SIMATIC S7-1500 Software Controller (V20.8). The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a specially crafted HTTP request.
Severity
No CVSS data available.
CWE
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T13:30:21.823Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-700697.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC ET 200SP Open Controller (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V20.8"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) (V20.8), SIMATIC S7-1500 Software Controller (V20.8). The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a specially crafted HTTP request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-14T21:05:18.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-700697.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-15796",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "V20.8"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) (V20.8), SIMATIC S7-1500 Software Controller (V20.8). The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a specially crafted HTTP request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-700697.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-700697.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-15796",
    "datePublished": "2020-12-14T21:05:18.000Z",
    "dateReserved": "2020-07-15T00:00:00.000Z",
    "dateUpdated": "2024-08-04T13:30:21.823Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-14348 (GCVE-0-2020-14348)

Vulnerability from cvelistv5 – Published: 2020-09-16 17:43 – Updated: 2024-08-04 12:39
VLAI
Summary
It was found in AMQ Online before 1.5.2 that injecting an invalid field to a user's AddressSpace configuration of the user namespace puts AMQ Online in an inconsistent state, where the AMQ Online components do not operate properly, such as the failure of provisioning and the failure of creating addresses, though this does not impact upon already existing messaging clients or brokers.
Severity
No CVSS data available.
CWE
References
Impacted products
Vendor Product Version
n/a AMQ Affected: AMQ Online before 1.5.2
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:39:36.482Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1861814"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AMQ",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "AMQ Online before 1.5.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "It was found in AMQ Online before 1.5.2 that injecting an invalid field to a user\u0027s AddressSpace configuration of the user namespace puts AMQ Online in an inconsistent state, where the AMQ Online components do not operate properly, such as the failure of provisioning and the failure of creating addresses, though this does not impact upon already existing messaging clients or brokers."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-16T17:43:39.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1861814"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2020-14348",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "AMQ",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "AMQ Online before 1.5.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "It was found in AMQ Online before 1.5.2 that injecting an invalid field to a user\u0027s AddressSpace configuration of the user namespace puts AMQ Online in an inconsistent state, where the AMQ Online components do not operate properly, such as the failure of provisioning and the failure of creating addresses, though this does not impact upon already existing messaging clients or brokers."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=1861814",
              "refsource": "MISC",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1861814"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2020-14348",
    "datePublished": "2020-09-16T17:43:39.000Z",
    "dateReserved": "2020-06-17T00:00:00.000Z",
    "dateUpdated": "2024-08-04T12:39:36.482Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10604 (GCVE-0-2020-10604)

Vulnerability from cvelistv5 – Published: 2020-07-24 23:34 – Updated: 2024-08-04 11:06
VLAI
Summary
In OSIsoft PI System multiple products and versions, a remote, unauthenticated attacker could crash PI Network Manager service through specially crafted requests. This can result in blocking connections and queries to PI Data Archive.
Severity
No CVSS data available.
CWE
  • CWE-248 - UNCAUGHT EXCEPTION CWE-248
References
Impacted products
Vendor Product Version
n/a OSIsoft PI System multiple products and versions Affected: OSIsoft PI System multiple products and versions
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:06:09.997Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-133-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OSIsoft PI System multiple products and versions",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "OSIsoft PI System multiple products and versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In OSIsoft PI System multiple products and versions, a remote, unauthenticated attacker could crash PI Network Manager service through specially crafted requests. This can result in blocking connections and queries to PI Data Archive."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "UNCAUGHT EXCEPTION CWE-248",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-24T23:34:55.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-133-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-10604",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OSIsoft PI System multiple products and versions",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "OSIsoft PI System multiple products and versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In OSIsoft PI System multiple products and versions, a remote, unauthenticated attacker could crash PI Network Manager service through specially crafted requests. This can result in blocking connections and queries to PI Data Archive."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "UNCAUGHT EXCEPTION CWE-248"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-133-02",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-133-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-10604",
    "datePublished": "2020-07-24T23:34:55.000Z",
    "dateReserved": "2020-03-16T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:06:09.997Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10292 (GCVE-0-2020-10292)

Vulnerability from cvelistv5 – Published: 2020-11-06 11:20 – Updated: 2024-09-17 04:29
VLAI
Title
Service DoS through arbitrary pointer dereferencing on KUKA simulator
Summary
Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol is vulnerable to DoS through an arbitrary pointerderreference. This flaw allows an attacker to to pass a specially crafted package that, when processed by theservice, causes an arbitrary pointer from the stack to be dereferenced, causing an uncaught exception thatterminates the service. This can be further contructed in combination with RVDP#710 which exploits an informationdisclosure leak, or with RVDP#711 for an stack-overflow and potential code execution.Beyond denying simulations, Visual Components provides capabilities to interface with industrial machinery andautomate certain processes (e.g. testing, benchmarking, etc.) which depending on the DevOps setup might beintegrated into the industrial flow. Accordingly, a DoS in the simulation might have higher repercusions, dependingon the Industrial Control System (ICS) ICS infrastructure.
CWE
References
Impacted products
Date Public
2020-11-06 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:58:40.018Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.visualcomponents.com/products/visual-components/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Visual Components Network License Server 2.0.8",
          "vendor": "KUKA Roboter GmbH",
          "versions": [
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Sharon Brizinov (Claroty)"
        }
      ],
      "datePublic": "2020-11-06T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol is vulnerable to DoS through an arbitrary pointerderreference. This flaw allows an attacker to to pass a specially crafted package that, when processed by theservice, causes an arbitrary pointer from the stack to be dereferenced, causing an uncaught exception thatterminates the service. This can be further contructed in combination with RVDP#710 which exploits an informationdisclosure leak, or with RVDP#711 for an stack-overflow and potential code execution.Beyond denying simulations, Visual Components provides capabilities to interface with industrial machinery andautomate certain processes (e.g. testing, benchmarking, etc.) which depending on the DevOps setup might beintegrated into the industrial flow. Accordingly, a DoS in the simulation might have higher repercusions, dependingon the Industrial Control System (ICS) ICS infrastructure."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-06T11:20:12.000Z",
        "orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
        "shortName": "Alias"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.visualcomponents.com/products/visual-components/"
        }
      ],
      "source": {
        "defect": [
          "RVD#712"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Service DoS through arbitrary pointer dereferencing on KUKA simulator",
      "x_generator": {
        "engine": "Robot Vulnerability Database (RVD)"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@aliasrobotics.com",
          "DATE_PUBLIC": "2020-11-06T11:14:41 +00:00",
          "ID": "CVE-2020-10292",
          "STATE": "PUBLIC",
          "TITLE": "Service DoS through arbitrary pointer dereferencing on KUKA simulator"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Visual Components Network License Server 2.0.8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "KUKA Roboter GmbH"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Sharon Brizinov (Claroty)"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol is vulnerable to DoS through an arbitrary pointerderreference. This flaw allows an attacker to to pass a specially crafted package that, when processed by theservice, causes an arbitrary pointer from the stack to be dereferenced, causing an uncaught exception thatterminates the service. This can be further contructed in combination with RVDP#710 which exploits an informationdisclosure leak, or with RVDP#711 for an stack-overflow and potential code execution.Beyond denying simulations, Visual Components provides capabilities to interface with industrial machinery andautomate certain processes (e.g. testing, benchmarking, etc.) which depending on the DevOps setup might beintegrated into the industrial flow. Accordingly, a DoS in the simulation might have higher repercusions, dependingon the Industrial Control System (ICS) ICS infrastructure."
            }
          ]
        },
        "generator": {
          "engine": "Robot Vulnerability Database (RVD)"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "high",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.visualcomponents.com/products/visual-components/",
              "refsource": "CONFIRM",
              "url": "https://www.visualcomponents.com/products/visual-components/"
            }
          ]
        },
        "source": {
          "defect": [
            "RVD#712"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
    "assignerShortName": "Alias",
    "cveId": "CVE-2020-10292",
    "datePublished": "2020-11-06T11:20:12.790Z",
    "dateReserved": "2020-03-10T00:00:00.000Z",
    "dateUpdated": "2024-09-17T04:29:05.653Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-6019 (GCVE-0-2020-6019)

Vulnerability from cvelistv5 – Published: 2020-11-13 15:03 – Updated: 2024-08-04 08:47
VLAI
Summary
Valve's Game Networking Sockets prior to version v1.2.0 improperly handles inlined statistics messages in function CConnectionTransportUDPBase::Received_Data(), leading to an exception thrown from libprotobuf and resulting in a crash.
Severity
No CVSS data available.
CWE
References
Impacted products
Vendor Product Version
n/a Game Networking Sockets Affected: All versions prior to v1.2.0
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:47:41.004Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/ValveSoftware/GameNetworkingSockets/commit/d944a10808891d202bb1d5e1998de6e0423af678"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://research.checkpoint.com/2020/game-on-finding-vulnerabilities-in-valves-steam-sockets/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Game Networking Sockets",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to v1.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Valve\u0027s Game Networking Sockets prior to version v1.2.0 improperly handles inlined statistics messages in function CConnectionTransportUDPBase::Received_Data(), leading to an exception thrown from libprotobuf and resulting in a crash."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-10T17:45:22.000Z",
        "orgId": "897c38be-0345-43cd-b6cf-fe179e0c4f45",
        "shortName": "checkpoint"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/ValveSoftware/GameNetworkingSockets/commit/d944a10808891d202bb1d5e1998de6e0423af678"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://research.checkpoint.com/2020/game-on-finding-vulnerabilities-in-valves-steam-sockets/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@checkpoint.com",
          "ID": "CVE-2020-6019",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Game Networking Sockets",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to v1.2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Valve\u0027s Game Networking Sockets prior to version v1.2.0 improperly handles inlined statistics messages in function CConnectionTransportUDPBase::Received_Data(), leading to an exception thrown from libprotobuf and resulting in a crash."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/ValveSoftware/GameNetworkingSockets/commit/d944a10808891d202bb1d5e1998de6e0423af678",
              "refsource": "MISC",
              "url": "https://github.com/ValveSoftware/GameNetworkingSockets/commit/d944a10808891d202bb1d5e1998de6e0423af678"
            },
            {
              "name": "https://research.checkpoint.com/2020/game-on-finding-vulnerabilities-in-valves-steam-sockets/",
              "refsource": "MISC",
              "url": "https://research.checkpoint.com/2020/game-on-finding-vulnerabilities-in-valves-steam-sockets/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "897c38be-0345-43cd-b6cf-fe179e0c4f45",
    "assignerShortName": "checkpoint",
    "cveId": "CVE-2020-6019",
    "datePublished": "2020-11-13T15:03:31.000Z",
    "dateReserved": "2020-01-07T00:00:00.000Z",
    "dateUpdated": "2024-08-04T08:47:41.004Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5129 (GCVE-0-2020-5129)

Vulnerability from cvelistv5 – Published: 2020-03-26 03:35 – Updated: 2024-08-04 08:22
VLAI
Summary
A vulnerability in the SonicWall SMA1000 HTTP Extraweb server allows an unauthenticated remote attacker to cause HTTP server crash which leads to Denial of Service. This vulnerability affected SMA1000 Version 12.1.0-06411 and earlier.
Severity
No CVSS data available.
CWE
References
Impacted products
Vendor Product Version
SonicWall SMA1000 Affected: 12.1.0-06411 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:22:08.523Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2020-0002"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SMA1000",
          "vendor": "SonicWall",
          "versions": [
            {
              "status": "affected",
              "version": "12.1.0-06411 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the SonicWall SMA1000 HTTP Extraweb server allows an unauthenticated remote attacker to cause HTTP server crash which leads to Denial of Service. This vulnerability affected SMA1000 Version 12.1.0-06411 and earlier."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-26T03:35:12.000Z",
        "orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
        "shortName": "sonicwall"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2020-0002"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "PSIRT@sonicwall.com",
          "ID": "CVE-2020-5129",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SMA1000",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "12.1.0-06411 and earlier"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SonicWall"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the SonicWall SMA1000 HTTP Extraweb server allows an unauthenticated remote attacker to cause HTTP server crash which leads to Denial of Service. This vulnerability affected SMA1000 Version 12.1.0-06411 and earlier."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2020-0002",
              "refsource": "CONFIRM",
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2020-0002"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
    "assignerShortName": "sonicwall",
    "cveId": "CVE-2020-5129",
    "datePublished": "2020-03-26T03:35:12.000Z",
    "dateReserved": "2019-12-31T00:00:00.000Z",
    "dateUpdated": "2024-08-04T08:22:08.523Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10931 (GCVE-0-2019-10931)

Vulnerability from cvelistv5 – Published: 2019-07-11 21:17 – Updated: 2024-08-04 22:40
VLAI
Summary
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.
Severity
No CVSS data available.
CWE
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.283Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "DIGSI 5 engineering software",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.90"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.90"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 device types 7SS85 and 7KE85",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.01"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.59"
            }
          ]
        },
        {
          "product": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.59"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-10T16:15:57.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10931",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "DIGSI 5 engineering software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.90"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.90"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC 5 device types 7SS85 and 7KE85",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.01"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.59"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.59"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions \u003c V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions \u003c V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-899560.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10931",
    "datePublished": "2019-07-11T21:17:47.000Z",
    "dateReserved": "2019-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T22:40:15.283Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10917 (GCVE-0-2019-10917)

Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 22:40
VLAI
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
References
Impacted products
Vendor Product Version
Siemens AG SIMATIC PCS 7 V8.0 and earlier Affected: All versions
Create a notification for this product.
Siemens AG SIMATIC PCS 7 V8.1 Affected: All versions < V8.1 with WinCC V7.3 Upd 19
Create a notification for this product.
Siemens AG SIMATIC PCS 7 V8.2 Affected: All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11
Create a notification for this product.
Siemens AG SIMATIC PCS 7 V9.0 Affected: All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11
Create a notification for this product.
Siemens AG SIMATIC WinCC (TIA Portal) V13 Affected: All versions
Create a notification for this product.
Siemens AG SIMATIC WinCC (TIA Portal) V14 Affected: All versions < V14 SP1 Upd 9
Create a notification for this product.
Siemens AG SIMATIC WinCC (TIA Portal) V15 Affected: All versions < V15.1 Upd 3
Create a notification for this product.
Siemens AG SIMATIC WinCC Runtime Professional V13 Affected: All versions
Create a notification for this product.
Siemens AG SIMATIC WinCC Runtime Professional V14 Affected: All versions < V14.1 Upd 8
Create a notification for this product.
Siemens AG SIMATIC WinCC Runtime Professional V15 Affected: All versions < V15.1 Upd 3
Create a notification for this product.
Siemens AG SIMATIC WinCC V7.2 and earlier Affected: All versions
Create a notification for this product.
Siemens AG SIMATIC WinCC V7.3 Affected: All versions < V7.3 Upd 19
Create a notification for this product.
Siemens AG SIMATIC WinCC V7.4 Affected: All versions < V7.4 SP1 Upd 11
Create a notification for this product.
Siemens AG SIMATIC WinCC V7.5 Affected: All versions < V7.5 Upd 3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.224Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd 9"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1 Upd 8"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 Upd 3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T19:28:02.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10917",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd 9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.1 Upd 8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 Upd 3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10917",
    "datePublished": "2019-05-14T19:54:48.000Z",
    "dateReserved": "2019-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T22:40:15.224Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-7474 (GCVE-0-2019-7474)

Vulnerability from cvelistv5 – Published: 2019-04-02 17:20 – Updated: 2024-08-04 20:46
VLAI
Summary
A vulnerability in SonicWall SonicOS and SonicOSv, allow authenticated read-only admin to leave the firewall in an unstable state by downloading certificate with specific extension. This vulnerability affected SonicOS Gen 5 version 5.9.1.10 and earlier, Gen 6 version 6.2.7.3, 6.5.1.3, 6.5.2.2, 6.5.3.1, 6.2.7.8, 6.4.0.0, 6.5.1.8, 6.0.5.3-86o and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V).
Severity
No CVSS data available.
CWE
References
Impacted products
Vendor Product Version
SonicWall SonicOS Affected: 5.9.1.10 and earlier
Affected: 6.2.7.3
Affected: 6.5.1.3
Affected: 6.5.2.2
Affected: 6.5.3.1
Affected: 6.2.7.8
Affected: 6.4.0.0
Affected: 6.5.1.8
Affected: 6.0.5.3-86o
Create a notification for this product.
SonicWall SonicOSv Affected: 6.5.0.2-8v_RC363 (VMWARE)
Affected: 6.5.0.2.8v_RC367 (AZURE)
Affected: 6.5.0.2.8v_RC368 (AWS)
Affected: 6.5.0.2.8v_RC366 (HYPER_V)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:46:46.349Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0001"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SonicOS",
          "vendor": "SonicWall",
          "versions": [
            {
              "status": "affected",
              "version": "5.9.1.10 and earlier"
            },
            {
              "status": "affected",
              "version": "6.2.7.3"
            },
            {
              "status": "affected",
              "version": "6.5.1.3"
            },
            {
              "status": "affected",
              "version": "6.5.2.2"
            },
            {
              "status": "affected",
              "version": "6.5.3.1"
            },
            {
              "status": "affected",
              "version": "6.2.7.8"
            },
            {
              "status": "affected",
              "version": "6.4.0.0"
            },
            {
              "status": "affected",
              "version": "6.5.1.8"
            },
            {
              "status": "affected",
              "version": "6.0.5.3-86o"
            }
          ]
        },
        {
          "product": "SonicOSv",
          "vendor": "SonicWall",
          "versions": [
            {
              "status": "affected",
              "version": "6.5.0.2-8v_RC363 (VMWARE)"
            },
            {
              "status": "affected",
              "version": "6.5.0.2.8v_RC367 (AZURE)"
            },
            {
              "status": "affected",
              "version": "6.5.0.2.8v_RC368 (AWS)"
            },
            {
              "status": "affected",
              "version": "6.5.0.2.8v_RC366 (HYPER_V)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in SonicWall SonicOS and SonicOSv, allow authenticated read-only admin to leave the firewall in an unstable state by downloading certificate with specific extension. This vulnerability affected SonicOS Gen 5 version 5.9.1.10 and earlier, Gen 6 version 6.2.7.3, 6.5.1.3, 6.5.2.2, 6.5.3.1, 6.2.7.8, 6.4.0.0, 6.5.1.8, 6.0.5.3-86o and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-02T17:20:39.000Z",
        "orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
        "shortName": "sonicwall"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0001"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "PSIRT@sonicwall.com",
          "ID": "CVE-2019-7474",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SonicOS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "5.9.1.10 and earlier"
                          },
                          {
                            "version_value": "6.2.7.3"
                          },
                          {
                            "version_value": "6.5.1.3"
                          },
                          {
                            "version_value": "6.5.2.2"
                          },
                          {
                            "version_value": "6.5.3.1"
                          },
                          {
                            "version_value": "6.2.7.8"
                          },
                          {
                            "version_value": "6.4.0.0"
                          },
                          {
                            "version_value": "6.5.1.8"
                          },
                          {
                            "version_value": "6.0.5.3-86o"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SonicOSv",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "6.5.0.2-8v_RC363 (VMWARE)"
                          },
                          {
                            "version_value": "6.5.0.2.8v_RC367 (AZURE)"
                          },
                          {
                            "version_value": "6.5.0.2.8v_RC368 (AWS)"
                          },
                          {
                            "version_value": "6.5.0.2.8v_RC366 (HYPER_V)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SonicWall"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in SonicWall SonicOS and SonicOSv, allow authenticated read-only admin to leave the firewall in an unstable state by downloading certificate with specific extension. This vulnerability affected SonicOS Gen 5 version 5.9.1.10 and earlier, Gen 6 version 6.2.7.3, 6.5.1.3, 6.5.2.2, 6.5.3.1, 6.2.7.8, 6.4.0.0, 6.5.1.8, 6.0.5.3-86o and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0001",
              "refsource": "CONFIRM",
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0001"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
    "assignerShortName": "sonicwall",
    "cveId": "CVE-2019-7474",
    "datePublished": "2019-04-02T17:20:39.000Z",
    "dateReserved": "2019-02-06T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:46:46.349Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

No mitigation information available for this CWE.

No CAPEC attack patterns related to this CWE.