CWE-1328
AllowedSecurity Version Number Mutable to Older Versions
Abstraction: Base · Status: Draft
Security-version number in hardware is mutable, resulting in the ability to downgrade (roll-back) the boot firmware to vulnerable code versions.
13 vulnerabilities reference this CWE, most recent first.
GHSA-MCCJ-PQ5M-H2MP
Vulnerability from github – Published: 2025-07-30 03:30 – Updated: 2025-07-30 03:30Tesla Wall Connector Firmware Downgrade Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Tesla Wall Connector devices. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the firmware upgrade feature. The issue results from the lack of an anti-downgrade mechanism. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-26299.
{
"affected": [],
"aliases": [
"CVE-2025-8321"
],
"database_specific": {
"cwe_ids": [
"CWE-1328"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-07-30T01:15:26Z",
"severity": "MODERATE"
},
"details": "Tesla Wall Connector Firmware Downgrade Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Tesla Wall Connector devices. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the firmware upgrade feature. The issue results from the lack of an anti-downgrade mechanism. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the device. Was ZDI-CAN-26299.",
"id": "GHSA-mccj-pq5m-h2mp",
"modified": "2025-07-30T03:30:35Z",
"published": "2025-07-30T03:30:35Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-8321"
},
{
"type": "WEB",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-25-712"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GHSA-QH98-G57P-5CPX
Vulnerability from github – Published: 2025-06-26 21:31 – Updated: 2025-06-26 21:31Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.
The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.
{
"affected": [],
"aliases": [
"CVE-2025-5825"
],
"database_specific": {
"cwe_ids": [
"CWE-1328"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2025-06-25T18:15:23Z",
"severity": "HIGH"
},
"details": "Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.",
"id": "GHSA-qh98-g57p-5cpx",
"modified": "2025-06-26T21:31:13Z",
"published": "2025-06-26T21:31:13Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2025-5825"
},
{
"type": "WEB",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-25-344"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GHSA-V8GH-HQFC-C796
Vulnerability from github – Published: 2026-09-10 18:31 – Updated: 2026-09-10 18:31Dell ThinOS 10, versions prior to 2605_10.2616, contain a Security Version Number Mutable to Older Versions vulnerability. A low privileged attacker with physical access could potentially exploit this vulnerability, leading to Protection mechanism bypass.
{
"affected": [],
"aliases": [
"CVE-2026-81051"
],
"database_specific": {
"cwe_ids": [
"CWE-1328"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2026-09-10T16:17:57Z",
"severity": "MODERATE"
},
"details": "Dell ThinOS 10, versions prior to 2605_10.2616, contain a Security Version Number Mutable to Older Versions vulnerability. A low privileged attacker with physical access could potentially exploit this vulnerability, leading to Protection mechanism bypass.",
"id": "GHSA-v8gh-hqfc-c796",
"modified": "2026-09-10T18:31:45Z",
"published": "2026-09-10T18:31:45Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2026-81051"
},
{
"type": "WEB",
"url": "https://www.dell.com/support/kbdoc/en-us/000502746/dsa-2026-389-security-update-for-dell-thinos-10-for-multiple-vulnerabilities"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
Mitigation
When architecting the system, security version data should be designated for storage in registers that are either read-only or have access controls that prevent modification by an untrusted agent.
Mitigation
During implementation and test, security version data should be demonstrated to be read-only and access controls should be validated.
CAPEC-176: Configuration/Environment Manipulation
An attacker manipulates files or settings external to a target application which affect the behavior of that application. For example, many applications use external configuration files and libraries - modification of these entities or otherwise affecting the application's ability to use them would constitute a configuration/environment manipulation attack.